Mostrar el registro sencillo del ítem

dc.contributor.authorFernandes T.L.
dc.contributor.authorRibeiro D.B.
dc.contributor.authorDa Rocha D.C.
dc.contributor.authorAlbuquerque C.
dc.contributor.authorPereira C.A.M.
dc.contributor.authorPedrinelli A.
dc.contributor.authorHernandez A.J.
dc.date.accessioned2019-08-20T00:13:11Z
dc.date.accessioned2023-05-03T20:37:48Z
dc.date.available2019-08-20T00:13:11Z
dc.date.available2023-05-03T20:37:48Z
dc.date.issued2014
dc.identifier.citationFERNANDES, TIAGO LAZZARETTI; ROCHA, D. C.; BADILLO, D.; Albuquerque, C.; PEREIRA, C. A.; PEDRINELLI, A.; HERNANDEZ, ARNALDO JOSÉ. Descrição de sistema de avaliação da cinemática do joelho em lesões ligamentares a partir de rastreamento óptico e tomografia 3D. Revista Brasileira de Ortopedia (Impresso), n. 8, p. 513-519, 2014.
dc.identifier.issn1982-4378
dc.identifier.urihttps://hdl.handle.net/20.500.12032/89456
dc.description.abstract© 2014 Sociedade Brasileira de Ortopedia e Traumatologia.Objective: To describe and demonstrate the viability of a method for evaluating knee kinematics, by means of a continuous passive motion (CPM) machine, before and after anterior cruciate ligament (ACL) injury.Methods: This study was conducted on a knee from a cadaver, in a mechanical pivot-shift simulator, with evaluations using optical tracking, and also using computed tomography.Results: This study demonstrated the viability of a protocol for measuring the rotation and translation of the knee, using reproducible and objective tools (error < 0.2 mm). The mechanized provocation system of the pivot-shift test was independent of the examiner and always allowed the same angular velocity and traction of 20 N throughout the movement.Conclusion: The clinical relevance of this method lies in making inferences about the in vivo behavior of a knee with an ACL injury and providing greater methodological quality in future studies for measuring surgical techniques with grafts in relatively close positions.
dc.relation.ispartofRevista Brasileira de Ortopedia
dc.rightsAcesso Aberto
dc.titleDescription of an evaluation system for knee kinematics in ligament lesions, by means of optical tracking and 3D tomography Descrição de sistema de avaliação da cinemática do joelho em lesões ligamentares a partir de rastreamento óptico e tomografia 3D
dc.typeArtigo


Ficheros en el ítem

FicherosTamañoFormatoVer

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem


© AUSJAL 2022

Asociación de Universidades Confiadas a la Compañía de Jesús en América Latina, AUSJAL
Av. Santa Teresa de Jesús Edif. Cerpe, Piso 2, Oficina AUSJAL Urb.
La Castellana, Chacao (1060) Caracas - Venezuela
Tel/Fax (+58-212)-266-13-41 /(+58-212)-266-85-62

Nuestras redes sociales

facebook Facebook

twitter Twitter

youtube Youtube

Asociaciones Jesuitas en el mundo
Ausjal en el mundo AJCU AUSJAL JESAM JCEP JCS JCAP