dc.contributor.advisorBruno Eizo Higakipt_BR
dc.contributor.authorMuniz, Clarice Farias
dc.contributor.authorAfonso, Fernando Cirilo Teruel
dc.contributor.authorCazac, Guilherme Cassimiro Schunck
dc.contributor.authorSilva, Talles Martins da
dc.date.accessioned2023-03-01T15:44:18Z
dc.date.accessioned2023-05-03T20:25:36Z
dc.date.available2023-03-01T15:44:18Z
dc.date.available2023-05-03T20:25:36Z
dc.date.issued2021-06-17
dc.identifier.urihttps://hdl.handle.net/20.500.12032/88513
dc.description.abstractO sistema Light Steel Framing (LSF) é um sistema construtivo industrializado de concepção racional e rápida execução. O mesmo é composto por perfis leves formados a frio, o fechamento pode ser realizado com placas cimentícias, gesso acartonado ou tiras de madeira orientadas. Com a industrialização do Light Steel Framing vem as vantagens de uma obra racional com o mínimo de erros possíveis, o que reduz a quantidade de entulho e sujeira. Com o crescimento do sistema LSF no Brasil é necessário estudos analitos da estrutura, o que vai proporcionar mais segurança e eficácia. Considerando esse contexto, o trabalho teve como objetivo a análise de um edifício de 5 pavimentos, contendo em cada pavimento 2 apartamentos. Nessa análise foi feito o estudo dos efeitos de primeira ordem dos deslocamentos laterais conforme cada tipo de contraventamento e de sua posição. Com o auxílio do software mCalcLSF, foram formuladas diferentes modelos estruturais com diferentes arranjos dos contraventamentos (X, V e K) visando encontrar um sistema que apresente melhor desempenho estrutural, ou seja menor deslocamento horizontal.pt_BR
dc.description.abstractThe Light Steel Framing system (LSF) is an industrialized construction system with rapid rational conception and quick execution. Said system is composed by light cold formed profiles, the closing can be performed with cement plaques, rounded plaster, or wood-oriented strips. With the introduction of Light Steel Framing, comes the advantages of a rational construction with minimal base error, that reduces the quantity of waste and dirt. Also, with the growing of the LSF in Brazil, it is necessary analytical studies of the structure itself, which provides more security and efficiency. In that context, the project had as it’s objective the analysis of a 5-story building, each containing 2 apartments. In this same analysis a study of the effects of the first and second order of lateral displacements according to each type of bracing and it’s position. With help of the mCalcLSF software, different structural models with different arrangements of bracings (X, V and K) were developed, with the objective of finding a system that represents better structural performance, or a minor horizontal displacement.en
dc.format.extent161pt_BR
dc.language.isopt_BRpt_BR
dc.rightsRestritopt_BR
dc.subjectanálise estruturalpt_BR
dc.subjectdeslocamentopt_BR
dc.subjectcontraventamentopt_BR
dc.subjectstructural analysispt_BR
dc.subjectdisplacementpt_BR
dc.subjectbracingpt_BR
dc.titleAnálise estrutural do contraventamento do steel framept_BR
dc.typeTrabalho de Conclusão de Cursopt_BR


Ficheros en el ítem

FicherosTamañoFormatoVer
Análise estrutu ... s no Steel Framing (1).pdf8.798Mbapplication/pdfVer/

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem


© AUSJAL 2022

Asociación de Universidades Confiadas a la Compañía de Jesús en América Latina, AUSJAL
Av. Santa Teresa de Jesús Edif. Cerpe, Piso 2, Oficina AUSJAL Urb.
La Castellana, Chacao (1060) Caracas - Venezuela
Tel/Fax (+58-212)-266-13-41 /(+58-212)-266-85-62

Nuestras redes sociales

facebook Facebook

twitter Twitter

youtube Youtube

Asociaciones Jesuitas en el mundo
Ausjal en el mundo AJCU AUSJAL JESAM JCEP JCS JCAP