dc.description.abstract | Based on the energy crises experienced in Brazil, initiatives were implemented
to reduce, conserve, and improve the use of electric energy in public buildings. The
publication of Instruction nº 02/2014 by the Ministério do Planejamento, Orçamento e
Gestão – MPOG made it mandatory to obtain the “A” (maximum) rating of the
Etiqueta Nacional de Conservação de Energia – ENCE for projects and construction
sites in the sphere of the Federal Public Administration. As a procedure for obtaining
this standard, existing projects or buildings should be submitted for analysis and
classification of their energy efficiency using the methods provided in Instrução
Normativa Inmetro para a Classificação de Eficiência Energética de Edificações
Comerciais, de Serviços e Públicas - INI-C. This research aimed to analyze the
potential for expanding the energy efficiency of the envelope of a public educational
building model by proposing strategies to improve its performance. For the case
study, an architectural model was elaborated with the characteristics and physical
properties of the constructive elements commonly adopted by the Universidade
Federal de Alfenas - Unifal-MG. Using the simplified method provided in the
regulations, the envelope of the model was classified with level “A” of efficiency.
Although its classification obtained the highest level, improvement strategies were
proposed aiming at a reduction of the total thermal load of refrigeration to enhance its
efficiency. The strategies addressed interventions in the glazing of the openings, in
the roof, in the external walls and the angle of vertical shading. By adopting this set
of strategies, reductions around 18,36% can be achieved in relation to the thermal
loads calculated for the basic model. | en |
dc.description.sponsorship | Nenhuma | pt_BR |
dc.language | pt_BR | pt_BR |
dc.publisher | Universidade do Vale do Rio dos Sinos | pt_BR |
dc.rights | openAccess | pt_BR |
dc.subject | Eficiência energética | pt_BR |
dc.subject | Energy efficiency | en |
dc.title | Análise da eficiência energética da envoltória de edifícios públicos segundo a Instrução normativa Inmetro para edificações comerciais, de serviços e públicas – INI-C: estudo de caso na UNIFAL-MG | pt_BR |
dc.type | Dissertação | pt_BR |