Mostrar el registro sencillo del ítem

dc.creatorPassos, Adriana Maria Monteiro
dc.date.accessioned2018-04-11T18:44:16Z
dc.date.accessioned2023-03-22T17:30:12Z
dc.date.available2023-03-22T17:30:12Z
dc.date.issued2013-06-03
dc.identifier.citationPASSOS, Adriana Maria Monteiro. Verificação da tendência de penetração de cloretos em corpos de prova parcialmente imersos em água do mar Recife, PE. 2013. 83 f. Dissertação (Mestrado) - Universidade Católica de Pernambuco. Pró-reitoria Acadêmica. Coordenação Geral de Pós-graduação. Mestrado em Engenharia Civil, 2013.por
dc.identifier.urihttps://hdl.handle.net/20.500.12032/76509
dc.description.abstractUrban concrete or reinforced concrete structures built in saline environments, under either intermittent or continuous sea water exposure, usually present mechanical wear and structure pathology problems that require relentless maintenance care. Currently, Brazil has a large number of civil construction equipment and buildings under direct or near direct contact with the sea and the city of Recife, Pernambuco State capital, for one, figures among the top most exposed cities in terms of number of urban equipment in contact with sea water, including buildings, bridges, mooring sites, footbridges, piers, i.e., design projects that essentially imply concrete structures located under diverse marine exposure conditions such as underwater or partially submersed structures, or structures located in tidal zones or areas under mist or sea water splash environments. Sea water carries rather high chloride ion contents, hence making those exposed structures especially vulnerable. A chloride penetration study was carried out according to ISO TC 71/SC 1 (07/26/2010 release), ISO/WD 1920-11, ISO TC 71/SC 1/WG SII, and Brazilian ABNT NBR 12655 standards. Concrete core samples of several strength levels were kept partially submerged in sea water; chloride ion contents and penetration depths were recorded. Furthermore, a number of chemical analyses have been conducted in order to estimate chloride contents present at several depths in various concrete samples prepared with several W/C ratios, hence with different strength values. According to what one might expect, laboratory assays indicated that the deeper the axial sample taken from the exposed core for analysis and the more concentrated the concrete Water/Cement ratio, the lower the chloride penetration. Therefore, the chloride ion penetration rate indeed decreases as the W/C ratio gets richer, when compared to average and poor W/C ratios for all sampled penetration depths analyzed.eng
dc.formatapplication/pdf*
dc.languageporpor
dc.publisherUniversidade Católica de Pernambucopor
dc.rightsAcesso Abertopor
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/
dc.subjectdissertationseng
dc.subjectConcrete - Corrosioneng
dc.subjectchlorideseng
dc.subjectConcreteeng
dc.subjectMohr, Method ofeng
dc.subjectDissertaçõespor
dc.subjectConcreto armado - Corrosãopor
dc.subjectCloretospor
dc.subjectConcretopor
dc.subjectMohr, Método depor
dc.titleVerificação da tendência de penetração de cloretos em corpos de prova parcialmente imersos em água do mar Recife, PEpor
dc.typeDissertaçãopor


Ficheros en el ítem

FicherosTamañoFormatoVer
adriana_maria_monteiro_passos.pdf4.108Mbapplication/pdfVer/

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Acesso Aberto
Excepto si se señala otra cosa, la licencia del ítem se describe como Acesso Aberto

© AUSJAL 2022

Asociación de Universidades Confiadas a la Compañía de Jesús en América Latina, AUSJAL
Av. Santa Teresa de Jesús Edif. Cerpe, Piso 2, Oficina AUSJAL Urb.
La Castellana, Chacao (1060) Caracas - Venezuela
Tel/Fax (+58-212)-266-13-41 /(+58-212)-266-85-62

Nuestras redes sociales

facebook Facebook

twitter Twitter

youtube Youtube

Asociaciones Jesuitas en el mundo
Ausjal en el mundo AJCU AUSJAL JESAM JCEP JCS JCAP