Mostrar registro simples

dc.contributor.authorPreciado, Adolfo
dc.contributor.authorOrduña, Agustín
dc.contributor.authorBartoli, Gianni
dc.contributor.authorBudelmann, Harald
dc.coverage.spatialColima, Méxicoes
dc.coverage.temporal1880-2015es
dc.date.accessioned2016-05-18T17:34:12Z
dc.date.accessioned2023-03-16T20:09:02Z
dc.date.available2016-05-18T17:34:12Z
dc.date.available2023-03-16T20:09:02Z
dc.date.issued2015-01
dc.identifier.citationPreciado, A., Orduña, A, Bartoli, G. and Budelmann, H. (2015). “Façade seismic failure simulation of an old Cathedral in Colima, Mexico by 3D Limit Analysis and Nonlinear Finite Element Method”. Journal of Engineering Failure Analysis, 49: pp. 20-30.es
dc.identifier.issn1350-6307
dc.identifier.urihttps://hdl.handle.net/20.500.12032/72509
dc.descriptionEarthquake protection of historical buildings is fundamental for the economy and development of a country and is a topic of intensive research among the scientific community. Two different material models and approaches such as 3D Limit Analysis and nonlinear Finite Element Method are used and compared for the seismic evaluation of an old masonry Cathedral in Colima, Mexico. It has been strongly damaged by a M7.6 earthquake in 1941, generating strong damage to the main façade with the collapse of the left tower. It was damaged again by a similar event of M7.5 in 2003. Both events mainly damaged the main façade including both bell-towers. In this paper, firstly, the Cathedral is completely modeled and a macro-element representing the observed most damaged part is selected. The seismic assessment results by both, Limit Analysis and nonlinear Finite Element approaches are able to simulate the observed failure mechanisms at the frontal façade and the obtained seismic coefficients are in good agreement. Moreover, the advantages and disadvantages through the seismic analysis process corresponding to the pre-processing, analysis and post-processing by the use of both approaches are detailed.es
dc.description.sponsorshipTechnical University of Braunschweiges
dc.description.sponsorshipUniversity of Florencees
dc.description.sponsorshipUniversity of Colimaes
dc.description.sponsorshipPolytechnical University of Guadalajaraes
dc.language.isoenges
dc.publisherElsevieres
dc.relation.ispartofseriesEngineering Failure Analysis;49
dc.rights.urihttp://quijote.biblio.iteso.mx/licencias/CC-BY-NC-ND-2.5-MX.pdfes
dc.subjectFaçadeses
dc.subjectPerformancees
dc.subjectStrong Earthquakeses
dc.subjectHistorical Masonryes
dc.subjectSeismic Assessmentes
dc.subjectFailure Mechanismses
dc.subjectNonlinear Analysises
dc.titleFaçade seismic failure simulation of an old Cathedral in Colima, Mexico by 3D Limit Analysis and Nonlinear Finite Element Methodes
dc.typeinfo:eu-repo/semantics/articlees


Arquivos deste item

ArquivosTamanhoFormatoVisualização
Author EFA Faca ... re Preciado et al 2015.pdf1.331Mbapplication/pdfVisualizar/Abrir

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples


© AUSJAL 2022

Asociación de Universidades Confiadas a la Compañía de Jesús en América Latina, AUSJAL
Av. Santa Teresa de Jesús Edif. Cerpe, Piso 2, Oficina AUSJAL Urb.
La Castellana, Chacao (1060) Caracas - Venezuela
Tel/Fax (+58-212)-266-13-41 /(+58-212)-266-85-62

Nuestras redes sociales

facebook Facebook

twitter Twitter

youtube Youtube

Asociaciones Jesuitas en el mundo
Ausjal en el mundo AJCU AUSJAL JESAM JCEP JCS JCAP