Mostrar el registro sencillo del ítem

dc.contributor.authorPreciado, Adolfo
dc.contributor.authorSperbeck, Silvio T.
dc.contributor.authorRamírez-Gaytán, Alejandro
dc.coverage.spatialEuropees
dc.coverage.temporal2000-2016es
dc.date.accessioned2016-05-27T17:15:07Z
dc.date.accessioned2023-03-10T16:54:30Z
dc.date.available2016-05-27T17:15:07Z
dc.date.available2023-03-10T16:54:30Z
dc.date.issued2016-05
dc.identifier.citationPreciado, A., Sperbeck, S. T. and Ramirez-Gaytan, A. (2016). “Seismic vulnerability enhancement of medieval and masonry bell towers externally prestressed with unbonded smart tendons”. Journal of Engineering Structures, Vol.122, pp.50-61.es
dc.identifier.issn0141-0296
dc.identifier.urihttps://hdl.handle.net/20.500.12032/69467
dc.descriptionMedieval and masonry bell towers are highly vulnerable to suffer strong earthquake damage due to the mechanical and physical characteristics of masonry and other important factors. An approach for the seismic vulnerability reduction of masonry towers with external prestressing is proposed. The devices are vertically and externally located in order to be removable when needed. The characteristic flexural failure mode of medieval towers and the shear mechanism of bell towers are simulated. Both failure modes are in agreement with earthquake damage in similar towers. Medium prestressing level enhances force capacity of towers failing by bending without reducing ductility. High prestressing level slightly reduces the displacement capability of towers failing ductile. In case of belfry failure, both prestressing levels permit to increase displacement but lower force than towers failing by bending. The proposed medium prestressing level is the optimal for masonry towers and other slender structures failing by bending and shear.es
dc.description.sponsorshipITESO, A.C.es
dc.description.sponsorshipTechnical University of Braunschweiges
dc.description.sponsorshipUniversity of Florencees
dc.language.isoenges
dc.publisherElsevieres
dc.relation.ispartofseriesJournal of Engineering Structures;122
dc.rights.urihttp://quijote.biblio.iteso.mx/licencias/CC-BY-NC-ND-2.5-MX.pdfes
dc.subjectEarthquakeses
dc.subjectTowerses
dc.subjectFailureses
dc.subjectSmart materialses
dc.subjectHistorical Masonryes
dc.subjectEnergy Dissipationes
dc.subjectExternal Prestressinges
dc.subjectUnbonded Tendonses
dc.subjectSmart Materialses
dc.titleSeismic vulnerability enhancement of medieval and masonry bell towers externally prestressed with unbonded smart tendonses
dc.typeinfo:eu-repo/semantics/articlees


Ficheros en el ítem

FicherosTamañoFormatoVer
Author ENGSTRUC ... nt Preciado et al 2016.pdf1.297Mbapplication/pdfVer/

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem


© AUSJAL 2022

Asociación de Universidades Confiadas a la Compañía de Jesús en América Latina, AUSJAL
Av. Santa Teresa de Jesús Edif. Cerpe, Piso 2, Oficina AUSJAL Urb.
La Castellana, Chacao (1060) Caracas - Venezuela
Tel/Fax (+58-212)-266-13-41 /(+58-212)-266-85-62

Nuestras redes sociales

facebook Facebook

twitter Twitter

youtube Youtube

Asociaciones Jesuitas en el mundo
Ausjal en el mundo AJCU AUSJAL JESAM JCEP JCS JCAP