Show simple item record

dc.contributor.authorPreciado, Adolfo
dc.contributor.authorBudelmann, Harald
dc.contributor.authorBartoli, Gianni
dc.date.accessioned2018-01-30T18:26:07Z
dc.date.accessioned2023-03-10T16:00:43Z
dc.date.available2018-01-30T18:26:07Z
dc.date.available2023-03-10T16:00:43Z
dc.date.issued2016-03-30
dc.identifier.citationPreciado, A., Budelmann, H. and Bartoli, G. (2016). Earthquake protection of colonial bell towers in Colima, Mexico with externally prestressed FRPs.International Journal of Architectural Heritage, 10(4): 499-515, ISSN: 1558-3058. http://www.tandfonline.com/doi/full/10.1080/15583058.2014.1003624es
dc.identifier.urihttps://hdl.handle.net/20.500.12032/68242
dc.descriptionA methodology for the seismic vulnerability reduction of old masonry towers with external prestressing is presented. It is applied at the Colonial bell-towers of the Cathedral of Colima, Mexico, characterized for being a high seismic area (M>7.5). The 3D FE models are calibrated with experimental data and assessed through nonlinear static approaches including the seismic demand and an accurate validated masonry model. Based on an extensive parametric study on different configurations of old masonry towers, it is selected an optimal prestressing force and device. The Colonial towers are retrofitted with four prestressing devices of FRPs to convert them into a high energy-dissipative reinforced masonry. The external vertical prestressing is included at key points identified in the seismic vulnerability assessment. This technique is in compliance with the demand for architectural conservation and may be located without drilling and unbounded in order to be fully removable. The seismic performance is enhanced by increasing force, displacement, and internal confinement. It is observed an upgrading of 35% and 20% of displacement capacity. With these results it is corroborated that external vertical prestressing allows a substantial increment of ductility for seismic energy dissipation purposes.es
dc.language.isoenges
dc.publisherTaylor & Francises
dc.rights.urihttp://quijote.biblio.iteso.mx/licencias/CC-BY-NC-ND-2.5-MX.pdfes
dc.subjectbell towerses
dc.subjectenergy dissipationes
dc.subjectFRP deviceses
dc.subjecthistorical masonryes
dc.subjectnonlinear assessmentses
dc.subjectretrofittinges
dc.titleEarthquake protection of colonial bell-towers in Colima, Mexico with externally prestressed FRPses
dc.typeinfo:eu-repo/semantics/articlees


Files in this item

FilesSizeFormatView
Author Version ... rs Preciado et al 2015.pdf1.719Mbapplication/pdfView/Open

This item appears in the following Collection(s)

Show simple item record


© AUSJAL 2022

Asociación de Universidades Confiadas a la Compañía de Jesús en América Latina, AUSJAL
Av. Santa Teresa de Jesús Edif. Cerpe, Piso 2, Oficina AUSJAL Urb.
La Castellana, Chacao (1060) Caracas - Venezuela
Tel/Fax (+58-212)-266-13-41 /(+58-212)-266-85-62

Nuestras redes sociales

facebook Facebook

twitter Twitter

youtube Youtube

Asociaciones Jesuitas en el mundo
Ausjal en el mundo AJCU AUSJAL JESAM JCEP JCS JCAP