Show simple item record

dc.contributor.advisorTutikian, Bernardo Fonseca
dc.contributor.authorSimonetti, Camila
dc.date.accessioned2020-10-07T20:25:58Z
dc.date.accessioned2022-09-22T19:40:30Z
dc.date.available2020-10-07T20:25:58Z
dc.date.available2022-09-22T19:40:30Z
dc.date.issued2020-05-25
dc.identifier.urihttps://hdl.handle.net/20.500.12032/63668
dc.description.abstractThe inappropriate disposal of waste tires represents a major concern regarding the mitigation of sanitary and environmental impacts from this action. This issue has motivated several studies on possible methods for reusing these elements. Civil construction can be a potential consumer of this type of waste due to the following reasons: its capacity for consuming large amounts of materials, its search for alternatives to overcome the shortage of raw materials, its interest in reducing the environmental footprint from construction projects, and its capacity to encapsulate contaminants in the cement matrix. The possibility of incorporating waste tires residue into concrete has already been consolidated in several previous studies, but there is a gap in the knowledge about how the concrete made with recycled tire materials behaves when exposed to high temperatures. This study aims to investigate the performance of precast concrete panels made with waste tires residues when exposed to fire when using the recycled steel fiber and the recycled rubber aggregate separately. The experimental design consisted in essays for the characterization of the physical and mechanical properties of the concrete produced with the recycled materials, as well as fire reactions and fire resistance tests. Besides the reference concrete without any residues, mixtures were prepared containing rubber particles used as partial replacement of fine aggregate at a proportion of 5% and 10% in volume, and other mixtures containing recycled steel fibers included at 0.5% and 1.5% of total volume. In terms of fire reaction, the results indicated that both groups of concretes with residues, unlike the conventional concrete, were classified as combustible due to the presence of sustained flaming during non-combustibility tests. There was neither flame propagation nor the register of smoke optical density. In the fire resistance tests, the recycled steel fiber reinforced concretes and those containing 5% recycled rubber aggregate presented similar behavior when compared to the conventional concrete on thermal insulation, sealing, and stability. The concrete made with 10% recycled rubber aggregate registered the occurrence of explosive spalling and worse thermal insulation and sealing.en
dc.description.sponsorshipPrograma de Incentivo Educacional e à Escola de Desenvolvimento de Servidores da UFRGSpt_BR
dc.languagept_BRpt_BR
dc.publisherUniversidade do Vale do Rio dos Sinospt_BR
dc.rightsopenAccesspt_BR
dc.subjectSegurança contra incêndiopt_BR
dc.subjectFire safetyen
dc.titleAvaliação do comportamento ao fogo de placas de vedação de concreto com inserção de resíduos de pneus inservíveispt_BR
dc.typeTesept_BR


Files in this item

FilesSizeFormatView
Camila Simonetti_.pdf8.047Mbapplication/pdfView/Open

This item appears in the following Collection(s)

Show simple item record


© AUSJAL 2022

Asociación de Universidades Confiadas a la Compañía de Jesús en América Latina, AUSJAL
Av. Santa Teresa de Jesús Edif. Cerpe, Piso 2, Oficina AUSJAL Urb.
La Castellana, Chacao (1060) Caracas - Venezuela
Tel/Fax (+58-212)-266-13-41 /(+58-212)-266-85-62

Nuestras redes sociales

facebook Facebook

twitter Twitter

youtube Youtube

Asociaciones Jesuitas en el mundo
Ausjal en el mundo AJCU AUSJAL JESAM JCEP JCS JCAP