Mostrar registro simples

dc.contributor.advisorGonzalez, Marco Aurélio Stumpf
dc.contributor.authorBrenner, Bruna Liliane
dc.date.accessioned2017-06-05T14:55:48Z
dc.date.accessioned2022-09-22T19:25:25Z
dc.date.available2017-06-05T14:55:48Z
dc.date.available2022-09-22T19:25:25Z
dc.date.issued2017-03-14
dc.identifier.urihttps://hdl.handle.net/20.500.12032/60697
dc.description.abstractThe need to minimize the environmental impacts caused by the most diverse human activities is more evident each year. This reality leads researchers to seek alternatives for optimizing the natural resources use such as water and energy. Energy from hydroelectric and thermoelectric sources is a widely used resource in Brazil, largely by buildings. Several discussions about increase energy efficiency in buildings therefore lead to the issue of thermal performance. As an alternative to solutions to increase the thermal performance with high cost, demand of specialized labor and increase of time to the work schedule in buildings, this research had as objective to analyze the effect of the use of thermal insulation inside the cavities of the ceramic blocks components of masonry. This is presented as an easier insulation option in relation to other techniques known in the market. The study was carried out through small scale prototype analyzes. Four experimental prototypes were constructed in São Leopoldo, RS, one of them being used as reference, representing the conventional construction form of the blocks masonry and the others with the cavities of its constituent blocks filled with three different thermal insulation types: EPS spheres, low density EPS and expanded perlite. In this research EPS was used in waste form from a company in the region. After the research, data collection and the results analysis, it was verified that the prototypes with insulation presented daily thermal oscillations minimally smaller in relation to the reference, being the lowest ones obtained by the prototype with low density EPS filling, followed by the expanded perlite and EPS spheres. Despite the fact that these diferences were very small, it is not possible to state that the use of thermal insulation inside the ceramic block cavities constituent of the masonry can bring benefits to the thermal performance in real buildings. The use of insulators in the form of residues was presented as an alternative to reduce costs with insulation.en
dc.description.sponsorshipCAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superiorpt_BR
dc.languagept_BRpt_BR
dc.publisherUniversidade do Vale do Rio dos Sinospt_BR
dc.rightsopenAccesspt_BR
dc.subjectComportamento térmicopt_BR
dc.subjectProtótiposen
dc.titleAvaliação da utilização de isolantes térmicos no interior das cavidades de blocos cerâmicos componentes de alvenarias de vedação externa para o clima de São Leopoldo, RSpt_BR
dc.typeDissertaçãopt_BR


Arquivos deste item

ArquivosTamanhoFormatoVisualização
Bruna Liliane Brenner_.pdf2.490Mbapplication/pdfVisualizar/Abrir

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples


© AUSJAL 2022

Asociación de Universidades Confiadas a la Compañía de Jesús en América Latina, AUSJAL
Av. Santa Teresa de Jesús Edif. Cerpe, Piso 2, Oficina AUSJAL Urb.
La Castellana, Chacao (1060) Caracas - Venezuela
Tel/Fax (+58-212)-266-13-41 /(+58-212)-266-85-62

Nuestras redes sociales

facebook Facebook

twitter Twitter

youtube Youtube

Asociaciones Jesuitas en el mundo
Ausjal en el mundo AJCU AUSJAL JESAM JCEP JCS JCAP