dc.description.abstractPhotovoltaic grid-connected systems aims the conversion of solar energy into electrical energy. In Brazil, was recently given the first effective step with the publication by ANEEL Normative Resolution No. 482. This resolution published on 17 th April, 2012, enables domestic and commercial consumers have an energy microgeneration system (hydro, solar, wind, biomass or qualified cogeneration) connected to mains power and make compensation. In this work was mounted on an experimental character, in the Renewable Energy Laboratory of Unisinos, a photovoltaic grid-connected system that uses a microinverter model, and through this installation and monitoring, analyse the electrical and energetical behavior of the system. The system consists of a 255 Wp LG255S1C monocrystalline module, connected to a 215 W ENPHASE M215 microinverter. The monitoring period was 1 st August to 20 th December, 2014. A central acquisition of Agilent HP 34970A data was used to collect data irradiance in the plane of the PV array, current and voltage at the input and output of microinverter, temperature of a PV cell in the center of the PV module and the microinverter sink. It was also used as a measuring the energy analyzer Fluke 43B, which collects the data of active power, reactive power and apparent power injected into the grid by the system. Power quality indices as the total harmonic current distortion and displacement factor were also measured. The maximum daily average efficiency, considering the uncertainty, measured on the employed microinverter was 95.18 % and is similar than the daily average efficiency values of microinverters of first and second generation. The photovoltaic system monitored using the microinverter peaked overall performance of 0.93. The production maximum daily energy into alternating current was 1.49 kWh. It is estimated taking into account the value that the monthly production can achieved 44.7 kWh. This means a reduction of 58 % in the consumption of a residence considering the availability cost and that the system is installed in a residence with the northest comsumption whose the average monthly consumption is 120.00 kWh.en
dc.description.sponsorshipCAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superiorpt_BR
dc.languagept_BRpt_BR
dc.publisherUniversidade do Vale do Rio dos Sinospt_BR
dc.rightsopenAccesspt_BR
dc.subjectEnergia solar fotovoltaicapt_BR
dc.subjectPhotovoltaic solar energyen
dc.titleMonitoramento e análise de um sistema fotovoltaico conectado à rede com uso de microinversorpt_BR
dc.typeDissertaçãopt_BR


Files in this item

FilesSizeFormatView
Gabriela Schenkel_.pdf3.048Mbapplication/pdfView/Open

This item appears in the following Collection(s)

Show simple item record


© AUSJAL 2022

Asociación de Universidades Confiadas a la Compañía de Jesús en América Latina, AUSJAL
Av. Santa Teresa de Jesús Edif. Cerpe, Piso 2, Oficina AUSJAL Urb.
La Castellana, Chacao (1060) Caracas - Venezuela
Tel/Fax (+58-212)-266-13-41 /(+58-212)-266-85-62

Nuestras redes sociales

facebook Facebook

twitter Twitter

youtube Youtube

Asociaciones Jesuitas en el mundo
Ausjal en el mundo AJCU AUSJAL JESAM JCEP JCS JCAP