Show simple item record

[en] DEVELOPMENT OF ELECTROANALYTICALS METODOLOGY FOR DETERMINATION OF ZIDOVUDINE, LAMIVUDINE AND ZALCITABINE

dc.contributorPERCIO AUGUSTO MARDINI FARIAS
dc.creatorKATIA CHRISTINA LEANDRO ANTUNES
dc.date2004-10-14
dc.date.accessioned2022-09-21T21:44:09Z
dc.date.available2022-09-21T21:44:09Z
dc.identifierhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=5571@1
dc.identifierhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=5571@2
dc.identifierhttp://doi.org/10.17771/PUCRio.acad.5571
dc.identifier.urihttps://hdl.handle.net/20.500.12032/42939
dc.description[pt] O comportamento eletroquímico e o desenvolvimento de metodologias eletroanalíticas para a determinação de zidovudina (AZT), lamivudina (3TC) e zalcitabina (DDC) em medicamentos foram investigados no presente trabalhoatravés de técnicas voltamétricas. Estas substâncias possuem atividade antiretroviral, sendo utilizadas no tratamento de indivíduos portadores de HIV. AZT, 3TC e DDC sofrem redução na superfície do eletrodo de mercúrio. Ainfluência dos parâmetros eletroquímicos, tais como, velocidade de varredura, amplitude, natureza do eletrólito suporte e pH foram estudados para selecionar as melhores condições para quantificar estes princípios ativos em formulações farmacêuticas. A redução da zidovudina ocorre em apenas uma etapa, sendo esta atribuída à redução do grupo azida (-N3), originando em um pico de potencial de-970 mV vs Ag/AgCl (3 mol L-1), utilizando tampão fosfato, pH 8,0. A faixa linear encontrada foi de 0,25 a 1,25 mg L-1. O mecanismo de redução da zidovudina envolve a participação de 4 elétrons e 2 prótons. Adicionalmente novos estudos eletroquímicos foram desenvolvidos para a determinação de lamivudina e de zalcitabina através da voltametria em pulso diferencial em tampão Clark-Lubs, pH 2,0, onde se obteve um pico no potencial de -1160 e -1180 mV, respectivamente. Lamivudina obteve faixa linear de 2,28 a 8,85 mg L-1 e zalcitabina de 10,0 a 23,3 mg L-1. O mecanismo de redução destas drogas envolve a participação de números iguais de prótons e elétrons. Todas as metodologias desenvolvidas também foram validadas.
dc.description[en] The electrochemical behaviour and the development of an analytical methodology for the zidovudine (AZT), lamivudine (3TC) and zalcitabine (DDC)determination in drugs using voltammetrics techniques were the objectives of the current study. These drugs have been extensively used in the treatment of HIV patients because its antiretroviral activity. The AZT, 3TC and DDC are reduced at a hanging mercury drop electrode (HMDE). The influence of electroanalytical parameters such as, scan rate, amplitude, nature of the support electrolyte and pH in the signal was verified to select the best conditions for quantifying these drugs in pharmaceutical forms. The obtained results had showed AZT, in solution of pH 8.0 of phosphate buffer, with only one reduction in -970 mV vs Ag/AgCl (3 mol L-1). This peak is due to reduction of the azido group present on zidovudine molecule. The linear range of standards is from 0.25 to 1.25 mg L-1. The electrodic mechanism involving the participation of 4 electrons and 2 protons in the reduction of AZT molecules. News studies were development for lamivudine and zalcitabine determination by differential pulse voltammetry in solution of pH 2.0 of Clark-Lubs buffer, with only one reduction in - 1160 and -1180 mV, respectively. Lamivudine has been the linear range of standards from 2.28 to 8.85 mg L-1 and zalcitabine from 10.0 to 23.3 mg L-1. The mechanism of these drugs involving the participation of the same number of electrons and protons. All these analytical methods were validated.
dc.languagept
dc.publisherMAXWELL
dc.subject[pt] ZIDOVUDINA
dc.subject[pt] ZALCITABINA
dc.subject[pt] LAMIVUDINA
dc.subject[pt] ANTIRETROVIRAIS
dc.subject[pt] VOLTAMETRIA
dc.subject[en] ZIDOVUDINE
dc.subject[en] ZALCITABINE
dc.subject[en] LAMIVUDINE
dc.subject[en] ANTIRETROVIRAL
dc.subject[en] VOLTAMMETRY
dc.title[pt] DESENVOLVIMENTO DE METODOLOGIAS ELETROANALÍTICAS PARA A DETERMINAÇÃO DE ZIDOVUDINA, LAMIVUDINA E ZALCITABINA
dc.title[en] DEVELOPMENT OF ELECTROANALYTICALS METODOLOGY FOR DETERMINATION OF ZIDOVUDINE, LAMIVUDINE AND ZALCITABINE
dc.typeTEXTO


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record


© AUSJAL 2022

Asociación de Universidades Confiadas a la Compañía de Jesús en América Latina, AUSJAL
Av. Santa Teresa de Jesús Edif. Cerpe, Piso 2, Oficina AUSJAL Urb.
La Castellana, Chacao (1060) Caracas - Venezuela
Tel/Fax (+58-212)-266-13-41 /(+58-212)-266-85-62

Nuestras redes sociales

facebook Facebook

twitter Twitter

youtube Youtube

Asociaciones Jesuitas en el mundo
Ausjal en el mundo AJCU AUSJAL JESAM JCEP JCS JCAP