[pt] CONTROLE METROLÓGICO E INSTRUMENTAL DA AVALIAÇÃO DE AMOSTRAS BRANCAS TRATADAS COM ALVEJANTE ÓTICO
[en] METROLOGICAL AND INSTRUMENTAL EVALUATION CONTROL OF WHITE SAMPLES TREATED WITH FLUORESCENT WHITENING AGENTS
dc.contributor | ROBERT HIRSCHLER | |
dc.creator | JENNIFER KATHRIN GAY | |
dc.date | 2004-06-21 | |
dc.date.accessioned | 2022-09-21T21:43:51Z | |
dc.date.available | 2022-09-21T21:43:51Z | |
dc.identifier | https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=5074@1 | |
dc.identifier | https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=5074@2 | |
dc.identifier | http://doi.org/10.17771/PUCRio.acad.5074 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12032/42698 | |
dc.description | [pt] A avaliação de artigos brancos tratados com alvejantes ópticos, como eles são comuns em substratos têxteis, plásticos e de papel, é uma tarefa que tradicionalmente resulta em muitas divergências entre avaliações visuais realizadas em uma cabine padronizada e avaliações instrumentais realizadas com espectrofotômetros de refletância. Mesmo entre as avaliações visuais ou entre as avaliações instrumentais são encontradas diferenças muito além do aceitável. Uma das principais causas é a fluorescência dos alvejantes ópticos que é influenciada pela quantidade de radiação UV em relação com a radiação na faixa visível do espectro. O trabalho apresentado analisa as diferentes formas de avaliação, principalmente do ponto de vista da qualidade da distribuição espectral de potência do simulador de luz do dia. No caso das avaliações visuais, são testadas diferentes lâmpadas fluorescentes. Para as avaliações instrumentais, a calibração e o ajuste de UV em conjunto com as diferentes aberturas de medição são analisados. O objetivo é aprimorar os aspectos metrológicos da avaliação e contribuir para a sua padronização a fim de garantir a maior reprodutibilidade de resultados, um procedimento importante e almejado por todos os segmentos industriais que utilizam os alvejantes ópticos. | |
dc.description | [en] The evaluation of white objects treated with fluorescent whitening agents, such as they are commonly found on substrates like textiles, plastics and paper, is a task that traditionally leads to frequent controversy between the visual evaluations performed in a standardized light booth and the instrumental evaluations performed on reflectance spectrophotometers. Even between visual or instrumental evaluations the differences encountered are far beyond the acceptable. One of the main reasons is the fluorescence of the optical brightening agents that is influenced by the amount of UV radiation in relation to the amount of radiation in the visible range of the spectrum. The work presented analyses the different forms of evaluation, mainly from the point of view of the quality of the daylight simulators´ spectral power distribution. In the case of the visual evaluations, different fluorescent lamps are tested. For the instrumental evaluations, the UV calibration and adjustment are analyzed together with the different measurement apertures. The objective is to improve the metrological aspects of the evaluation and contribute to its standardization with the aim to guarantee better reproducibility of results, an important procedure that is desired by all the industrial segments that use optical brighteners. | |
dc.language | pt | |
dc.publisher | MAXWELL | |
dc.subject | [pt] FLUORESCENCIA | |
dc.subject | [pt] ESPECTROFOTOMETRO | |
dc.subject | [pt] SIMULADORES DE LUZ DO DIA | |
dc.subject | [pt] ALVEJANTE OPTICO | |
dc.subject | [pt] BRANCURA | |
dc.subject | [pt] AVALIACAO VISUAL | |
dc.subject | [en] FLUORESCENCE | |
dc.subject | [en] SPECTROPHOTOMETER | |
dc.subject | [en] DAYLIGHT SIMULATORS | |
dc.subject | [en] FLUORESCENT WHITENING AGENTS | |
dc.subject | [en] WHITENESS | |
dc.subject | [en] VISUAL EVALUATION | |
dc.title | [pt] CONTROLE METROLÓGICO E INSTRUMENTAL DA AVALIAÇÃO DE AMOSTRAS BRANCAS TRATADAS COM ALVEJANTE ÓTICO | |
dc.title | [en] METROLOGICAL AND INSTRUMENTAL EVALUATION CONTROL OF WHITE SAMPLES TREATED WITH FLUORESCENT WHITENING AGENTS | |
dc.type | TEXTO |
Files in this item
Files | Size | Format | View |
---|---|---|---|
There are no files associated with this item. |