[en] TRANSPORT COEFFICIENTS OF ICE SLURRY IN PLATE HEAT EXCHANGER

dc.contributorSERGIO LEAL BRAGA
dc.creatorHUGO GUILLERMO JIMENEZ PACHECO
dc.date2004-01-14
dc.date.accessioned2022-09-21T21:42:13Z
dc.date.available2022-09-21T21:42:13Z
dc.identifierhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=4382@1
dc.identifierhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=4382@2
dc.identifierhttp://doi.org/10.17771/PUCRio.acad.4382
dc.identifier.urihttps://hdl.handle.net/20.500.12032/42481
dc.description[pt] O uso da pasta de gelo começou recentemente a ser aplicado em sistemas de refrigeração e condicionamento de ar. Como principais vantagens deste fluido, podem ser citados: a possibilidade de armazenar calor latente do gelo e a possibilidade de ser bombeado como a água fria. Assim, o pasta de gelo pode ser usado para o armazenamento térmico no lugar da água fria ou do gelo, desde que, até determinadas concentrações, possa ser bombeado através dos trocadores de calor. Para que esta tecnologia seja aceita extensamente, informações de engenharia são requeridas nas características de transporte nos equipamentos de troca de calor. Um dispositivo experimental foi desenvolvido para estudar os coeficientes de transporte do pasta de gelo em um trocador de calor de placas, utilizando água como carga térmica a resfriar. Foram investigadas várias situações para diferentes frações iniciais e vazões do pasta de gelo. As condições de entrada da carga térmica, foram mantidas constantes. São monitoradas a temperatura, a queda de pressão, a fração do gelo sólido e a vazão do pasta de gelo no trocador de calor, assim como a vazão e a de temperatura na parte da carga térmica. Os resultados mostram que o coeficiente global de troca de calor aumenta com aumento da fração inicial do gelo. A capacidade do resfriamento do trocador de calor aumenta consideravelmente, em relação da água, quando a pasta de gelo, é utilizada como fluido secundário. Finalmente, a queda de pressão aumenta com o aumento da fração inicial de gelo.
dc.description[en] The use of the ice slurry is recently applied in the refrigeration and air conditioning systems. Advantages such as the possibility to store latent heat on ice and the possibility of being pumped as cold water can be considered. Ice slurries can be used both for cold storage in place of chilled water or ice and as a secondary refrigerant since, up to certain concentrations, they can be pumped directly through distribution pipeworks and heat exchangers. For ice slurries to become more widely accepted, however, more engineering information is required on fluid flow and heat transfer characteristics. An experimental device was developed to study the transport properties of the ice slurry in plate heat exchangers. Several situations were investigated for different initial fractions and flows of ice slurry. The conditions of the thermal load (pure water), had been kept constant. The temperature field, the pressure loss, the initial fraction and the flow of ice slurry are monitored in the heat exchanger, beyond the flow and the temperature field is monitored in the part of the thermal load. The overall heat transfer coefficient, increases in function of the initial ice fraction. The capacity cooling of the heat exchanger increases with the use of ice slurry when compared to pure water. Finally can be showed that the loss of pressure increases for higher initial ice fraction.
dc.languagept
dc.publisherMAXWELL
dc.subject[pt] MUDANCA DE FASE
dc.subject[pt] TERMOACUMULACAO
dc.subject[pt] FRACAO DE GELO
dc.subject[pt] PASTA DE GELO
dc.subject[pt] TROCADOR DE CALOR DE PLACAS
dc.subject[en] PHASE CHANGE
dc.subject[en] THERMAL STORAGE
dc.subject[en] ICE FRACTION
dc.subject[en] ICE SLURRY
dc.subject[en] PLATE HEAT EXCHANGER
dc.title[pt] COEFICIENTES DE TRANSPORTE DA PASTA DE GELO EM UM TROCADOR DE CALOR DE PLACAS
dc.title[en] TRANSPORT COEFFICIENTS OF ICE SLURRY IN PLATE HEAT EXCHANGER
dc.typeTEXTO


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record


© AUSJAL 2022

Asociación de Universidades Confiadas a la Compañía de Jesús en América Latina, AUSJAL
Av. Santa Teresa de Jesús Edif. Cerpe, Piso 2, Oficina AUSJAL Urb.
La Castellana, Chacao (1060) Caracas - Venezuela
Tel/Fax (+58-212)-266-13-41 /(+58-212)-266-85-62

Nuestras redes sociales

facebook Facebook

twitter Twitter

youtube Youtube

Asociaciones Jesuitas en el mundo
Ausjal en el mundo AJCU AUSJAL JESAM JCEP JCS JCAP