[en] DEVELOPMENT AND COMPARATIVE STUDY OF SPECTROFLUORIMETRIC AND VOLTAMMETRIC METHODOLOGIES FOR THE DETERMINATION OF THALIDOMIDE IN ONE COMMERCIAL FORMULATION, URINE AND BLOOD SERUM

dc.contributorRICARDO QUEIROZ AUCELIO
dc.creatorCARLOS EDUARDO CARDOSO
dc.date2003-07-21
dc.date.accessioned2022-09-21T21:41:51Z
dc.date.available2022-09-21T21:41:51Z
dc.identifierhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=3730@1
dc.identifierhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=3730@2
dc.identifierhttp://doi.org/10.17771/PUCRio.acad.3730
dc.identifier.urihttps://hdl.handle.net/20.500.12032/42135
dc.description[pt] No presente trabalho foram desenvolvidas duas metodologias analíticas para a determinação de talidomida, um composto de reconhecida importância farmacológica. As metodologias espectrofluorimétrica e voltamétrica desenvolvidas foram comparadas em termos de desempenho analítico.As características fluorescentes e eletroquímicas da talidomida foram estudadas para que se encontrassem condições experimentais que fornecessem máximo sinal fluorescente do analito em solução na temperatura ambiente e possibilidade de pré-concentração do analito no eletrodo de mercúrio.Nas condições experimentais otimizadas para a talidomida, limites de detecção compreendidos entre 10-6 e 10-9 g L-1 foram obtidos para o método espectrofluorimétrico e voltamétrico, respectivamente. Faixas lineares dinâmicas entre 2 e 4 ordens de grandeza foram alcançadas dependendo do método e do interferente presente na amostra. Esses parâmetros de mérito se mostraram adequados para o problema proposto. O possível efeito interferente de substâncias geralmente usadas em associação com o analito foi estudado, e estratégias para minimização das interferências foram desenvolvidas. Enquanto a tetraciclina não interferiu no método espectrofluorimétrico, o uso combinado de meio ácido e irradiação UV da amostra foi necessária para permitir a quantificação do analito em presença de sulfanilamida. Na voltametria, as interferências da tetraciclina e da sulfanilamida puderam ser compensadas pelo uso da quantificação pelo método de adição do analito. Nas determinações dos fluídos biológicos, o uso da extração em coluna de sílica C18 mostrou-se bastante eficiente na separação do analito dos interferentes da matriz para o método espectrofluorimétrico e para o voltamétrico, no caso do soro sangüíneo. Para a urina, apenas a clarificação da amostra com sulfato de amônio foi suficiente no caso da determinação voltamétrica.Os métodos desenvolvidos foram testados na dosagem de talidomida presente em uma formulação comercial e em amostras de urina e soro sangüíneo enriquecidas com o analito. Para tal, utilizaram-se os procedimentos de curva de calibração (espectrofluorimetria) e método da adição do analito (voltametria). Em todos os casos, as recuperações obtidas estiveram compreendidas na faixa de 96,5 a 107,6 %, dentro da faixa de recuperação estabelecida pela Farmacopéia dos Estados Unidos da América.
dc.description[en] In the present work two analytical methodologies were developed aiming the determination of thalidomide, an important pharmacological compound. The developed spectrofluorimetric and the voltammetric based analytical methodologies were compared in terms of analytical performance. The thalidomide fluorescent and the electrochemical characteristics were studied in order to find experimental conditions for maximum fluorescence in solution and at room temperature and to allow analyte pre- concentration on the mercury electrode. Using the optimized experimental conditions, limits of detection between 10-6 to 10-9 g L-1 were achieved respectively for the spectrofluorimetric method and for the voltammetric method. Dynamic linear ranges between 2 and 4 orders of magnitude were obtained depending on the method utilized and the interferent substances present in the sample. Those parameters of merit were suitable for this proposed analytical problem. The potential interference effect from substances usually used in association with thalidomide, were studied and strategies for the minimization of such interferences were developed. While no interference in the spectrofluorimetric method was observed for tetracycline, the combined use of acidic medium and UV irradiation of the samples was necessary to allow the analyte determination in the presence of sulfanilamide. For the voltammetric method, interferences from tetracycline and sulfanilamide could be compensated by quantifying thalidomide using the analyte addition method. For the determination in biological fluids, the use a solid-liquid extraction on a C18 column was found to be very effective for the analyte separation and elimination of matrix interferences for the spectrofluorimetric method and for the voltammetric method developed for blood serum. For urine samples, a clean-up step using ammonium sulfate was found to be sufficient for the voltammetric determination of thalidomide. The developed methodologies were tested by determining the thalidomide content in a commercial pharmaceutical formulation and in analyte spiked biological fluids using calibration curves (spectrofluorimetric) and analyte addition method (voltammetric). In all cases, the recoveries were between the 96,5 and 107,6 %, within the recovery range considered adequate according to the United States Pharmacopoeia.
dc.languagept
dc.publisherMAXWELL
dc.subject[pt] TALIDOMIDA
dc.subject[pt] SELETIVIDADE
dc.subject[pt] SORO SANGUINEO
dc.subject[pt] URINA
dc.subject[pt] FORMULACAO COMERCIAL
dc.subject[pt] DETERMINACAO
dc.subject[pt] VOLTAMETRIA DE PULSO DIFERENCIAL
dc.subject[pt] ESPECTROFLUORIMETRIA
dc.subject[en] THALIDOMIDE
dc.subject[en] SELECTIVITY
dc.subject[en] BLOOD SERUM
dc.subject[en] URINE
dc.subject[en] COMMERCIAL FORMULATION
dc.subject[en] DETERMINATION
dc.subject[en] STRIPPING VOLTAMMETRY
dc.subject[en] SPECTROFLUORIMETRY
dc.title[pt] DESENVOLVIMENTO E ESTUDO COMPARATIVO DE METODOLOGIAS ESPECTROFLUORIMÉTRICA E VOLTAMÉTRICA PARA A DETERMINAÇÃO DE TALIDOMIDA EM UM FÁRMACO, URINA E SORO SANGÜÍNEO
dc.title[en] DEVELOPMENT AND COMPARATIVE STUDY OF SPECTROFLUORIMETRIC AND VOLTAMMETRIC METHODOLOGIES FOR THE DETERMINATION OF THALIDOMIDE IN ONE COMMERCIAL FORMULATION, URINE AND BLOOD SERUM
dc.typeTEXTO


Ficheros en el ítem

FicherosTamañoFormatoVer

No hay ficheros asociados a este ítem.

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem


© AUSJAL 2022

Asociación de Universidades Confiadas a la Compañía de Jesús en América Latina, AUSJAL
Av. Santa Teresa de Jesús Edif. Cerpe, Piso 2, Oficina AUSJAL Urb.
La Castellana, Chacao (1060) Caracas - Venezuela
Tel/Fax (+58-212)-266-13-41 /(+58-212)-266-85-62

Nuestras redes sociales

facebook Facebook

twitter Twitter

youtube Youtube

Asociaciones Jesuitas en el mundo
Ausjal en el mundo AJCU AUSJAL JESAM JCEP JCS JCAP