[en] METROLOGICAL ESTIMATION OF THERMOELECTRIC STABILITY IN AUPT THERMOCOUPLE

dc.contributorALCIR DE FARO ORLANDO
dc.contributorALCIR DE FARO ORLANDO
dc.creatorMARCELO DOS SANTOS MONTEIRO
dc.date2003-06-26
dc.date.accessioned2022-09-21T21:41:48Z
dc.date.available2022-09-21T21:41:48Z
dc.identifierhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=3668@1
dc.identifierhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=3668@2
dc.identifierhttp://doi.org/10.17771/PUCRio.acad.3668
dc.identifier.urihttps://hdl.handle.net/20.500.12032/42102
dc.description[pt] Em 1990, com a adoção da Escala Internacional de Temperatura de 1990, o termopar de platina e platina/ródio deixou de ser o instrumento de interpolação entre 630 graus Celsius e 1064 graus Celsius, em virtude de sua pouca estabilidade, sendo a partir daí utilizados o termômetro de resistência de platina de alta temperatura (TRPAT) e o termômetro de radiação. Este estudo realiza uma investigação prática das características de um termopar de ouro e platina, ambos com pureza superior a 99,999 por cento, no que diz respeito à sua estabilidade termoelétrica e à homogeneidade de seus termoelementos, questionando a possibilidade de seu uso como alternativa ao emprego do TRPAT em processos de medição que exijam grande exatidão com custo mais baixo. Neste trabalho, o termopar estudado foi submetido a temperaturas próximas ao seu limite máximo de operação, que é de 1000 graus Celsius, por mais de 1500 horas, sendo avaliadas a sua estabilidade e a sua homogeneidade em função do tempo de uso, com o auxílio de uma célula de ponto fixo da prata do Inmetro, que é um padrão primário de temperatura.
dc.description[en] In 1990, with the adoption of the International Temperature Scale of 1990, the platinum/platinum-rhodium thermocouple was removed as the interpolation instrument between 630 graus Celsius and 1064 Celsius degrees, due its low stability, in favor of the high temperature standard platinum resistance thermometer (HTSPRT) and the radiation thermometer. In this work, it is performed a practical investigation of the characteristics of a 99,999 percent purity gold-platinum thermocouple, concerning its thermoelectric stability and homogeneity of its thermoelements, questioning the possibility of its use as an alternative to the HTSPRT in measurement processes requiring high accuracy with lower costs. In this work, the test thermocouple was exposed to temperatures close to its upper limit (1000 Celsius degrees) for more than 1500 hours, being its stability and homogeneity evaluated as function of time, with aid of a silver fixed point cell from Inmetro, that is a temperature primary standard.
dc.languagept
dc.publisherMAXWELL
dc.subject[pt] METROLOGIA
dc.subject[pt] OURO-PLATINA
dc.subject[pt] TERMOPAR
dc.subject[pt] TERMOMETRIA
dc.subject[en] METROLOGY
dc.subject[en] GOLD-PLATINUM
dc.subject[en] THERMOCOUPLE
dc.subject[en] THERMOMETRY
dc.title[pt] AVALIAÇÃO METROLÓGICA DA ESTABILIDADE TERMOELÉTRICA DE TERMOPAR AUPT
dc.title[en] METROLOGICAL ESTIMATION OF THERMOELECTRIC STABILITY IN AUPT THERMOCOUPLE
dc.typeTEXTO


Arquivos deste item

ArquivosTamanhoFormatoVisualização

Não existem arquivos associados a este item.

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples


© AUSJAL 2022

Asociación de Universidades Confiadas a la Compañía de Jesús en América Latina, AUSJAL
Av. Santa Teresa de Jesús Edif. Cerpe, Piso 2, Oficina AUSJAL Urb.
La Castellana, Chacao (1060) Caracas - Venezuela
Tel/Fax (+58-212)-266-13-41 /(+58-212)-266-85-62

Nuestras redes sociales

facebook Facebook

twitter Twitter

youtube Youtube

Asociaciones Jesuitas en el mundo
Ausjal en el mundo AJCU AUSJAL JESAM JCEP JCS JCAP