[en] COSTS ALLOCATION OF REACTIVE POWER DEVICES
[pt] IDENTIFICAÇÃO DOS BENEFICIÁRIOS E ALOCAÇÃO DE CUSTOS DE FONTES DE POTÊNCIA REATIVA
dc.contributor | RICARDO BERNARDO PRADA | |
dc.creator | GISELA APARECIDA SILVA N BARROS | |
dc.date | 2003-05-20 | |
dc.date.accessioned | 2022-09-21T21:40:22Z | |
dc.date.available | 2022-09-21T21:40:22Z | |
dc.identifier | https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=3511@1 | |
dc.identifier | https://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=3511@2 | |
dc.identifier | http://doi.org/10.17771/PUCRio.acad.3511 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12032/42055 | |
dc.description | [pt] No atual modelo econômico do setor elétrico, é necessário identificar os agentes beneficiados pelos serviços ancilares à transmissão de potência de forma a alocar adequadamente os custos de investimento, de operação e manutenção do equipamento necessário para a prestação do serviço. Entre os serviços ancilares, destaca-se o suporte de potência reativa para a regulação de tensão. Este trabalho apresenta um método baseado nos multiplicadores de Lagrange de um problema de otimização associado ao cálculo das medidas corretivas necessárias para lidar com níveis de tensão inadequados. Dois critérios de otimização são definidos: mínimo corte de carga e mínima alocação de potência reativa. Os multiplicadores de Lagrange definem a responsabilidade de cada barra quando ocorrem violações de tensão no sistema. O método permite não só identificar as barras beneficiadas pelo equipamento de compensação de potência reativa como também alocar os custos entre elas. É priorizada a confiabilidade do sistema, analisando as contingências possíveis e considerando suas respectivas probabilidades de ocorrência. O programa computacional NH2, desenvolvido pelo CEPEL, é a ferramenta básica para o desenvolvimento deste trabalho. O método é aplicado, a título de ilustração, ao sistema IEEE - RTS de 24 barras e ao sistema da Área Rio. Os resultados obtidos são comparados com um método já existente, que define fatores de alocação de custos medindo os benefícios às barras devido ao suporte de potência reativa. Esta comparação, benefício x responsabilidade, e a própria teoria dos dois métodos, mostram que o método proposto identifica mais adequadamente as barras e os respectivos fatores para a repartição dos custos. | |
dc.description | [en] It is important to identify the agents that take advantage of the ancillary services for system operation in the nowadays electricity market. The actual economic design requires that the costs of investment, operation and maintenance of the necessary equipment should be properly allocated between these agents. Among the ancillary services, the reactive power support for voltage regulation is quite important. It is presented a method that identifies the buses that take advantage of the reactive power equipment and allocates the costs between each one of them. The power system reliability is taken into account. The analysis considers possible contingencies and their respective probability of occurrence. The computer program NH2, developed by CEPEL, is the main tool for the development of this work. The method is based on the Lagrangian multipliers of an optimal power flow problem (OPF) associated to corrective measures necessary to deal with voltage violations. Two different objective functions are used: minimum load shedding and minimum reactive power injection. The Lagrangian multipliers define the responsibility of each bus when system voltage violations occur. For the purpose of illustration, the method is applied on the 24 bus IEEE Reliability Test System and on Área Rio system. Results are compared with those produced by other existing method that defines cost allocation factors measuring the benefit due the reactive support. This comparison, benefit x responsibility, and the theory used by both methods, show that the proposed method identifies more appropriately the buses and the corresponding factors to allocate the costs. | |
dc.language | pt | |
dc.publisher | MAXWELL | |
dc.subject | [pt] SERVICO ANCILAR | |
dc.subject | [pt] MULTIPLICADOR DE LAGRANGE | |
dc.subject | [pt] FLUXO DE POTENCIA OTIMO | |
dc.subject | [pt] CONFIABILIDADE | |
dc.subject | [pt] POTENCIA REATIVA | |
dc.subject | [en] ANCILLARY SERVICE | |
dc.subject | [en] LAGRANGE MULTIPLIER | |
dc.subject | [en] OPTIMAL POWER FLOW | |
dc.subject | [en] RELIABILITY | |
dc.subject | [en] REACTIVE POWER | |
dc.title | [en] COSTS ALLOCATION OF REACTIVE POWER DEVICES | |
dc.title | [pt] IDENTIFICAÇÃO DOS BENEFICIÁRIOS E ALOCAÇÃO DE CUSTOS DE FONTES DE POTÊNCIA REATIVA | |
dc.type | TEXTO |