Show simple item record

[pt] UM MÉTODO PARA O CÁLCULO DE FLUXO ÓTICO COM ESTIMATIVA DE CONFIABILIDADE

dc.contributorMARCELO DE ANDRADE DREUX
dc.contributorMARCELO DE ANDRADE DREUX
dc.creatorLUIZ EDUARDO A. SAUERBRONN
dc.date2002-06-03
dc.date.accessioned2022-09-21T21:40:10Z
dc.date.available2022-09-21T21:40:10Z
dc.identifierhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=2670@1
dc.identifierhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=2670@2
dc.identifierhttp://doi.org/10.17771/PUCRio.acad.2670
dc.identifier.urihttps://hdl.handle.net/20.500.12032/41891
dc.description[pt] Muitos sistemas biológicos utilizam visão como forma primária de sensoriamento.Ao longo de milhões de anos de evolução, as diferentes espécies vêm demonstrando o potencial associado à capacidade de visão. A partir da década de 60, foram iniciados os primeiros estudos no sentido de proporcionar às máquinas esta forma de sensoriamento. A esta nova forma de sensoriamento dá-se o nome de Visão Computacional. Em Visão Computacional, muitos casos requerem a determinação de um campo vetorial que descreva os deslocamentos ocorridos entre dois quadros consecutivos de uma seqüência genérica de vídeo. A este campo vetorial dá-se o nome de Optical Flow (Fluxo Ótico). A determinação do Optical Flow é ainda um problema sem solução. No presente trabalho, propõe-se um novo estimador estatístico para a determinação do Fluxo Ótico. Este estimador possui complexidade O(n) e associa um grau de confiabilidade a cada estimativa realizada. É aplicável a qualquer sinal digital (não apenas imagens ou vídeo, mas também a som, volume, etc) e vem demonstrando esultados muito promissores.
dc.description[en] Many biological systems make use of vision as its primary sensory mechanism. During million years, different species have been showing the great potential associated with vision. From the early sixties onwards, studies have been done to provide machines with this important sense. The research area involved in this task is called Computer Vision. In Computer Vision there are many situations where it is necessary to evaluate a vector field which describes existing displacements between two consecutive frames of a generic video sequence. This vector field is called Optical Flow. The Optical Flow determination is still a problem with unknown solution. This work proposes a new statistic algorithm to estimate the Optical Flow. The proposed algorithm has O(n) complexity and associates a degree of reliability to each estimation.The algorithm can be applied to any digital signal (not only images or videos, but also sound, volume etc) and is achieving promising results.
dc.languagept
dc.publisherMAXWELL
dc.subject[pt] ESTATISTICA
dc.subject[pt] VISAO COMPUTACIONAL
dc.subject[pt] FLUXO OTICO
dc.subject[en] STATISTICS
dc.subject[en] COMPUTER VISION
dc.subject[en] OPTICAL FLOW
dc.title[en] A METHOD FOR OPTICAL FLOW EVALUATION CONSIDERING RELIABILITY ESTIMATION
dc.title[pt] UM MÉTODO PARA O CÁLCULO DE FLUXO ÓTICO COM ESTIMATIVA DE CONFIABILIDADE
dc.typeTEXTO


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record


© AUSJAL 2022

Asociación de Universidades Confiadas a la Compañía de Jesús en América Latina, AUSJAL
Av. Santa Teresa de Jesús Edif. Cerpe, Piso 2, Oficina AUSJAL Urb.
La Castellana, Chacao (1060) Caracas - Venezuela
Tel/Fax (+58-212)-266-13-41 /(+58-212)-266-85-62

Nuestras redes sociales

facebook Facebook

twitter Twitter

youtube Youtube

Asociaciones Jesuitas en el mundo
Ausjal en el mundo AJCU AUSJAL JESAM JCEP JCS JCAP