Show simple item record

[pt] DETERMINAÇÃO DAS CARACTERÍSTICAS TRANSIENTES DE UM MEDIDOR DE PH: QUALIFICAÇÃO METROLÓGICA

dc.contributorALCIR DE FARO ORLANDO
dc.contributorALCIR DE FARO ORLANDO
dc.creatorELCIO CRUZ DE OLIVEIRA
dc.date2001-11-21
dc.date.accessioned2022-09-21T21:40:03Z
dc.date.available2022-09-21T21:40:03Z
dc.identifierhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=2129@1
dc.identifierhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=2129@2
dc.identifierhttp://doi.org/10.17771/PUCRio.acad.2129
dc.identifier.urihttps://hdl.handle.net/20.500.12032/41799
dc.description[pt] Os medidores de pH existentes no mercado indicam valores confiáveis, dentro de uma incerteza declarada para cada modelo fabricado. Entretanto, normalmente, não é citada a especificação em termos do tempo necessário para alcançar estes valores, devido ao tempo de resposta do instrumento. Esta dissertação de mestrado tem como objetivo desenvolver uma metodologia teórico-experimental para avaliar o desempenho do transdutor em condições transientes, indicando alguns valores típicos para medidores comerciais, e sua resposta na medição de pH, a partir do modelo testado em uma reação experimental, sendo o mesmo simulado em outras reações químicas para diferentes velocidades de reação.Através deste modelo qualificado, foram avaliados os erros devidos às respostas permanentes e transientes, mostrando em que condições o medidor de pH pode ser usado, a partir da comparação entre valores de pH real e valores de pH registrados pelo medidor, levando em consideração a temperatura e o tempo de reação.
dc.description[en] The electrochemical analysers available in the market assert trustworthy values applicable in a specific uncertainty range, which varies depending on the unit`s model.Nevertheless, rarely is given any information on the time necessary to reach these values, which depend on the answer of the instrument. This Master`s dissertation aims to develop an experimental theoretical methodology to evaluate the performance of the transducer in transient conditions, and obtain some typical values for commercial analysers, and its answer in the pH measurements in simulated chemical reactions in various reaction velocities. Through the qualified model, the errors due to the permanent and transient answers were evaluated, establishing the conditions pH electronic units can be used, in a pre-set controlled error, from the comparison between real pH values and displayed pH values in the analysers, considering the temperature and the reaction time.
dc.languagept
dc.publisherMAXWELL
dc.subject[pt] RESPOSTAS TRANSIENTES
dc.subject[pt] PH METRO
dc.subject[pt] TEMPO DE RESPOSTA
dc.subject[en] TRANSIENT ANSWERS
dc.subject[en] PH METER
dc.subject[en] RESPONSE TIME
dc.title[en] DETERMINATION OF THE TRANSIENT CHARACTERISTICS OF A PH ELECTROCHEMICAL ANALYSER: METROLOGICAL QUALIFICATION
dc.title[pt] DETERMINAÇÃO DAS CARACTERÍSTICAS TRANSIENTES DE UM MEDIDOR DE PH: QUALIFICAÇÃO METROLÓGICA
dc.typeTEXTO


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record


© AUSJAL 2022

Asociación de Universidades Confiadas a la Compañía de Jesús en América Latina, AUSJAL
Av. Santa Teresa de Jesús Edif. Cerpe, Piso 2, Oficina AUSJAL Urb.
La Castellana, Chacao (1060) Caracas - Venezuela
Tel/Fax (+58-212)-266-13-41 /(+58-212)-266-85-62

Nuestras redes sociales

facebook Facebook

twitter Twitter

youtube Youtube

Asociaciones Jesuitas en el mundo
Ausjal en el mundo AJCU AUSJAL JESAM JCEP JCS JCAP