Show simple item record

dc.contributor.advisorMartínez-Guerrero, Esteban
dc.contributor.advisorSinsel-Duarte, Martín A.
dc.contributor.authorRuiz-García, Vicente I.
dc.contributor.authorMartínez-Guerrero, Esteban
dc.contributor.authorSinsel-Duarte, Martín A.
dc.date.accessioned2026-08-18T19:15:50Z
dc.date.accessioned2026-10-21T19:32:26Z
dc.date.available2026-08-18T19:15:50Z
dc.date.available2026-10-21T19:32:26Z
dc.date.issued2026-08
dc.identifier.citationRuiz-García, V. I. (2026). Salivary Impedance-Based Glucose Sensing: a Hardware-Assisted Approach and Performance Evaluation. Trabajo de obtención de grado, Especialidad en Sistemas Embebidos. Tlaquepaque, Jalisco: ITESO.
dc.identifier.urihttps://hdl.handle.net/20.500.12032/191499
dc.description.abstractNon-invasive glucose monitoring faces significant reliability hurdles due to electrode polarization and low-amplitude signal interference in salivary sensing. This paper presents an integrated mixed-signal platform using the ADuCM350 system-on-chip to evaluate the feasibility of salivary bio-impedance analysis for glucose estimation. The methodology implements an isolated 4-wire Kelvin technique and hardware-accelerated DFT processing to mitigate contact impedance and systematic errors. While the system demonstrated high accuracy in characterizing Randles equivalent circuits, preliminary measurements with hydrogen peroxide (𝑯𝟐𝑶𝟐) solutions revealed significant challenges in electrochemical stability and signal-to-noise ratios. These results provide critical insights into the limitations of current portable architectures and highlight the need for further optimization in electrode-analyte interface stability for reliable non-invasive diagnostics.
dc.description.sponsorshipITESO, A. C.es
dc.language.isoeng
dc.publisherITESO
dc.rights.urihttps://creativecommons.org/licenses/by-nc/4.0/deed.es
dc.subjectADuCM350
dc.subjectBioimpedance
dc.subjectDigital Signal Processing
dc.subjectNon-Invasive Sensing
dc.titleSalivary Impedance-Based Glucose Sensing. A Hardware-Assisted Approach and Performance Evaluation
dc.typeinfo:eu-repo/semantics/academicSpecialization
dc.type.versioninfo:eu-repo/semantics/publishedVersion


Files in this item

FilesSizeFormatView
SalivaryImpedance-BasedGlucoseSensing_.pdf737.0Kbapplication/pdfView/Open

This item appears in the following Collection(s)

Show simple item record

https://creativecommons.org/licenses/by-nc/4.0/deed.es
Except where otherwise noted, this item's license is described as https://creativecommons.org/licenses/by-nc/4.0/deed.es

© AUSJAL 2022

Asociación de Universidades Confiadas a la Compañía de Jesús en América Latina, AUSJAL
Av. Santa Teresa de Jesús Edif. Cerpe, Piso 2, Oficina AUSJAL Urb.
La Castellana, Chacao (1060) Caracas - Venezuela
Tel/Fax (+58-212)-266-13-41 /(+58-212)-266-85-62

Nuestras redes sociales

facebook Facebook

twitter Twitter

youtube Youtube

Asociaciones Jesuitas en el mundo
Ausjal en el mundo AJCU AUSJAL JESAM JCEP JCS JCAP