Mostrar registro simples

dc.contributor.authorRODRIGUES, P. F.
dc.contributor.authorMOSCOVICI, B. K.
dc.contributor.authorHOEHNE, J. L.
dc.contributor.authorCAMPOS, M. S. D. Q.
dc.contributor.authorAndreia de Araújo Morandim Giannetti
dc.contributor.authorBERSANETTI, P. A.
dc.contributor.authorNOSE, W.
dc.date.accessioned2023-06-01T06:05:06Z
dc.date.accessioned2026-04-28T15:49:35Z
dc.date.available2023-06-01T06:05:06Z
dc.date.available2026-04-28T15:49:35Z
dc.date.issued2023-04-24
dc.identifier.citationRODRIGUES, P. F.; MOSCOVICI, B. K.; HOEHNE, J. L.; CAMPOS, M. S. D. Q.; GIANNETTI, A. DE . A. M.; BERSANETTI, P. A.; NOSE, W. Spectrophotometric analysis of different polymethyl methacrylate filters and their importance in the implantation of corneal rings. Current Eye Research, apr. 2023.
dc.identifier.issn1460-2202
dc.identifier.urihttps://hdl.handle.net/20.500.12032/186910
dc.description.abstract© 2023 Taylor & Francis Group, LLC.Purpose: This study evaluated the luminous behavior applied to materials used in intraocular surgeries. Methods: Discs of the different products were delivered in 19.00 mm × 3.00 mm. Each sample was fixed on support keeping it perpendicular to the spectrophotometer beam. Later, their analyses were carried out in the air/PMMA ratio. The graphs of individual profiles of the measurements along the length were constructed according to each of the filters from the spectrophotometric analysis. In addition, descriptive statistics of transmittance and absorbance for each wavelength presented were correlated for each filter. Results: It is possible to observe that the minimum absorption measure was found in the Red Filter, especially in the blue and green light spectrum. Conclusion: Using filters in PMMA materials appears to improve visual quality in corneal implants, especially the red filter, due to greater absorbance of light leading to fewer light scattering phenomena through corneal rings. However, further studies comparing the effects of different filters on Intracorneal rings should be carried out to elucidate this field of study.
dc.relation.ispartofCurrent Eye Research
dc.rightsAcesso Restrito
dc.titleSpectrophotometric Analysis of Different Polymethyl Methacrylate Filters and their Importance in the Implantation of Corneal Rings
dc.typeArtigo
dc.identifier.doi10.1080/02713683.2023.2202365
dc.subject.otherlanguagecorneal
dc.subject.otherlanguageFilters
dc.subject.otherlanguageimplantation
dc.subject.otherlanguagematerials
dc.subject.otherlanguagering
fei.scopus.citations0
fei.scopus.eid2-s2.0-85153588596
fei.scopus.urlhttps://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85153588596&origin=inward
fei.scopus.updated2026-01-27
dc.contributor.advisorOrcidhttps://orcid.org/0000-0002-5428-768X


Arquivos deste item

ArquivosTamanhoFormatoVisualização

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples


© AUSJAL 2022

Asociación de Universidades Confiadas a la Compañía de Jesús en América Latina, AUSJAL
Av. Santa Teresa de Jesús Edif. Cerpe, Piso 2, Oficina AUSJAL Urb.
La Castellana, Chacao (1060) Caracas - Venezuela
Tel/Fax (+58-212)-266-13-41 /(+58-212)-266-85-62

Nuestras redes sociales

facebook Facebook

twitter Twitter

youtube Youtube

Asociaciones Jesuitas en el mundo
Ausjal en el mundo AJCU AUSJAL JESAM JCEP JCS JCAP