Mostrar el registro sencillo del ítem

dc.contributor.advisorTutikian, Bernardo Fonseca
dc.contributor.authorTrevisan, Rafael
dc.date.accessioned2023-11-10T19:00:36Z
dc.date.accessioned2024-02-28T18:58:18Z
dc.date.available2023-11-10T19:00:36Z
dc.date.available2024-02-28T18:58:18Z
dc.date.issued2023-08-31
dc.identifier.urihttps://hdl.handle.net/20.500.12032/126623
dc.description.abstractOne of the main damages in reinforced concrete structures is the corrosion of the steel reinforcements. As an alternative to this scenario, there is the use of polymer bars reinforced with glass fiber (GFRP – Glass Fiber reinforced Polymer), increasing durability. The material also has reduced mass compared to steel bars and also high tensile strength. In order to use these bars, it is necessary to study their behavior in the face of accidents such as fires and the action of high temperatures, objective of this study. Specifically, the study evaluated the elastic modulus and direct tensile strength of the bars during and after exposure to high temperatures. The experimental program characterized the bar at room temperature. Afterward, the bars were tested during and after exposure to temperatures at levels of 150, 200, 250, 300, and 350 ºC. After exposure to high temperatures, the bars were evaluated with scanning electron microscopy (SEM), and the resin consumption was evaluated through the fiber content test. The indicated results indicate that the fiber content was in accordance with the assumptions of the IBRACON/ABECE recommended practices and international standards. Regarding exposure at high temperatures, it was noticed that the damage was more severe in the tests carried out during the high temperatures than in the bars after this exposure. The reduction in direct tensile strength reached 37% at a temperature of 350 °C. The greatest reduction in the modulus of elasticity, however, was 8.3%, indicating that the performance of the fibers was not so compromised even in the face of exposure to heat. For tests after exposure to high temperatures, the greatest reduction in tensile strength occurred at 150 ºC, being less than 1%. For the modulus of elasticity in this condition, the greatest reduction was 7.9%, observed at 200 ºC. The glass transition temperature obtained was 101.75 ºC. Through scanning electron microscopy, it was possible to perceive flaws that result from the consumption of resin due to the action of heat, such as: surface damage, flaws, less thickness of fiber cover, fiber breakage, among others. The fiber content test after high temperatures showed a direct relationship with the reduction of mechanical properties.pt_BR
dc.description.sponsorshipCAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superiorpt_BR
dc.languagept_BRpt_BR
dc.publisherUniversidade do Vale do Rio dos Sinospt_BR
dc.rightsopenAccesspt_BR
dc.subjectElevadas temperaturaspt_BR
dc.subjectHigh temperaturesen
dc.titleAnálise mecânica em elevadas temperaturas de barras poliméricas reforçadas com fibra de vidropt_BR
dc.typeDissertaçãopt_BR


Ficheros en el ítem

FicherosTamañoFormatoVer
Rafael Trevisan_PROTEGIDO.pdf9.325Mbapplication/pdfVer/

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem


© AUSJAL 2022

Asociación de Universidades Confiadas a la Compañía de Jesús en América Latina, AUSJAL
Av. Santa Teresa de Jesús Edif. Cerpe, Piso 2, Oficina AUSJAL Urb.
La Castellana, Chacao (1060) Caracas - Venezuela
Tel/Fax (+58-212)-266-13-41 /(+58-212)-266-85-62

Nuestras redes sociales

facebook Facebook

twitter Twitter

youtube Youtube

Asociaciones Jesuitas en el mundo
Ausjal en el mundo AJCU AUSJAL JESAM JCEP JCS JCAP