dc.contributor | Universidad Santo Tomás | spa |
dc.contributor.author | Gutiérrez Barreto, Javier Fernando; Universidad Santo Tomás. Bogotá, Colombia | |
dc.contributor.author | Castañeda Laborde, Claudia Marcela; Universidad Santo Tomás. Bogotá, Colombia | |
dc.contributor.author | León Zuluaga, Victoria; Universidad Santo Tomás. Bogotá, Colombia. | |
dc.contributor.author | Ortiz Andrade, Mayrim; Universidad Santo Tomás. Bogotá, Colombia | |
dc.date.accessioned | 2018-02-24T15:54:29Z | |
dc.date.accessioned | 2020-04-15T18:18:51Z | |
dc.date.accessioned | 2023-05-11T19:31:23Z | |
dc.date.available | 2018-02-24T15:54:29Z | |
dc.date.available | 2020-04-15T18:18:51Z | |
dc.date.available | 2023-05-11T19:31:23Z | |
dc.date.created | 2015-12-30 | |
dc.identifier | http://revistas.javeriana.edu.co/index.php/revUnivOdontologica/article/view/16028 | |
dc.identifier | 10.11144/Javeriana.uo34-73.epel | |
dc.identifier.issn | 2027-3444 | |
dc.identifier.issn | 0120-4319 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12032/115917 | |
dc.description.abstract | RESUMEN. Antecedentes: Es importante en la práctica clínica que los instrumentos rotatorios usados estén estériles para evitar infecciones cruzadas. Objetivo: Evaluar la efectividad del proceso de esterilización de las limas primarias WaveOne® con el propósito de fundamentar su reutilización. Métodos: Se evaluaron 50 limas primarias WaveOne®, 10 nuevas y 40 usadas en conductos mesovestibulares de molares con diagnóstico de periodontitis apical y necrosis pulpar. Las limas usadas se esterilizaron mediante la prueba de esterilidad establecida por la farmacopea 35 europea y japonesa. Resultados: Las 10 limas WaveOne® primarias, sin uso, no mostraron crecimiento de microorganismos. En el grupo 2, las 40 limas WaveOne® primarias usadas una vez y esterilizadas tampoco mostraron crecimiento de microorganismos. Conclusiones: El proceso de esterilización de las limas primarias WaveOne® fue satisfactorio. Además las limas primarias WaveOne®, como lo indica el fabricante, vienen estériles en su empaque.ABSTRACT. Background: It is important that rotary instruments used in clinical practice are sterile to avoid cross-infection. Objective: To evaluate the effectiveness of the sterilization process of Primary WaveOne® files, in order to support their reutilization. Methods: The sample consisted of 50 Primary WaveOne® files, 10 new and 40 used to prepare mesio-vestibular root canals of molars with diagnosis of pulp necrosis or apical periodontitis. Files in group 2 were sterilized and tested through the protocol described at the European and Japanese Pharmacopoeia 35. Results: The 10 new Primary WaveOne® files did not show microorganism growth. The 40 sterilized files of group 2 did not show growth of microorganisms either. Conclusions: The process of file sterilization was effective. In addition, WaveOne® Primary files, as indicated by the manufacturer, come in sterile packaging. | spa |
dc.format | PDF | spa |
dc.format.mimetype | application/pdf | spa |
dc.language.iso | spa | |
dc.publisher | Editorial Pontificia Universidad Javeriana | eng |
dc.relation.uri | http://revistas.javeriana.edu.co/index.php/revUnivOdontologica/article/view/16028/12829 | |
dc.rights | Copyright (c) 2015 Javier Fernando Gutiérrez Barreto, Claudia Marcela Castañeda Laborde, Victoria León Zuluaga, Mayrim Ortiz Andrade | eng |
dc.rights.uri | http://creativecommons.org/licenses/by/4.0 | eng |
dc.subject | endodoncia | spa |
dc.subject | endodoncia; esterilización; limas rotatorias níquel titanio; sistemas rotatorios; WaveOne | spa |
dc.title | Eficiencia del proceso de esterilización de las limas primarias WaveOne® / Effectiveness of Sterilization Process of Primary WaveOne® Files | spa |