Mostrar registro simples

dc.contributorRedes Temáticas de Colaboración Académica, Subsecretaría de Educación Pública, Programa de Mejoramiento del Profesorado (Promep), Mexicospa
dc.contributor.authorSánchez-Rubio Carrillo, Raúl Armando; Universidad Autónoma de Baja California
dc.contributor.authorEstrada Esquivel, Blanca Estela; Benemérita Universidad Autónoma de Puebla
dc.contributor.authorde Lima Moreno, Javier; Universidad de la República
dc.contributor.authorMontalvo Ramírez, Gustavo; Secretaría de Salud y Asistencia, Mexicali, Baja California
dc.contributor.authorRosales Ibáñez, Raúl; Universidad Autónoma de San Luis Potosí
dc.contributor.authorSánchez-Rubio Carrillo, Ricardo Manuel; Universidad Autónoma de Baja California
dc.date.accessioned2018-02-24T15:54:16Z
dc.date.accessioned2020-04-15T18:18:32Z
dc.date.accessioned2023-05-11T17:28:48Z
dc.date.available2018-02-24T15:54:16Z
dc.date.available2020-04-15T18:18:32Z
dc.date.available2023-05-11T17:28:48Z
dc.date.created2015-11-04
dc.identifierhttp://revistas.javeriana.edu.co/index.php/revUnivOdontologica/article/view/14224
dc.identifier10.11144/Javeriana.uo33-71.epip
dc.identifier.issn2027-3444
dc.identifier.issn0120-4319
dc.identifier.urihttps://hdl.handle.net/20.500.12032/108994
dc.description.abstractAntecedentes: se presentan las primeras fases de pruebas in vitro que refutan la hipótesis de que el material de 2-3 mm de plomo utilizado como protector en prótesis radíferas, durante radioterapia en pacientes oncológicos de cabeza y cuello, ayuda a reducir el depósito de dosis en los órganos sanos o de riesgo. Propósito: comprobar la efectividad del plomo para reducir la radiación terapéutica. Métodos: se realizaron pruebas in vitro con dos placas de plomo de 1 mm × 5 cm × 5 cm sobre una película radiocrómica Gafchromic RQTA2 “10 × 10”. Se aplicó, con acelerador lineal, una energía de 6 MeV en dosis promedio de 192 cGy de una fracción de dosis aplicables en teleterapia. También se efectuaron pruebas de contacto de 0,168 MeV de iridio 192 (braquiterapia) para una dosis de 300 cGy, la cual se aplica fraccionada bajo una cubierta de agua sólida (polímero de 2 cm de espesor con la misma densidad del agua). Se realizaron pruebas similares sin la protección de plomo en ambos casos (campo abierto) como control. Resultados: con la lectura de densidades de la película se encontró que en el tratamiento con iridio192 y 2 mm de plomo hubo una diferencia de aumento de radiación del 7,25 % con respecto al campo abierto (sin plomo). En el tratamiento con acelerador lineal a 6 MeV con 2 mm de plomo se observó un aumento de 16,25 % con respecto al campo abierto. Background: we present early-stage in vitro evidence supporting the hypothesis that 2-3 mm lead plaques used as shielding in prosthesis for the radiotherapy in head-and-neck cancer patients help reduce deposit dose in healthy or at risk organs. Purpose: to test the effect of lead in reducing therapeutic radiation. Methods: in vitro tests were performed with two 1 mm × 5 cm × 5 cm lead plates on a Gafchromic RQTA2 “10 × 10” chromic film. 6 MeV energy doses of 192 cGy applied with a linear accelerator as a fraction of applicable doses of teletherapy to test contact. Likewise, 168 MeV Iridium 192 (brachytherapy) were used for a 300 cGy dosis under a cover of solid water (2 cm thick polymer with the same density as water). Similar tests were performed without the lead protection in both cases (open field) as a control. Results: the density readings of the films showed, for the treatment with 2 mm lead Iridium 192, an increased difference of radiation of 7.25% compared to the open field. The treatment with linear accelerator with 6 MeV energy and 2 mm lead increased 16.25% compared to the open field.spa
dc.formatPDFspa
dc.format.mimetypeapplication/pdfspa
dc.language.isospa
dc.publisherEditorial Pontificia Universidad Javerianaeng
dc.relation.urihttp://revistas.javeriana.edu.co/index.php/revUnivOdontologica/article/view/14224/11625
dc.rightsCopyright (c) 2014 Universitas Odontologicaeng
dc.titleEfectividad de las prótesis intrabucales protectoras emplomadas en teleterapia y braquiterapia / Effectiveness of Intr aoral Pr otective Leaded Pr ostheses in Teletherapy and Brachytherapyspa


Arquivos deste item

ArquivosTamanhoFormatoVisualização

Este item aparece na(s) seguinte(s) coleção(s)

Mostrar registro simples


© AUSJAL 2022

Asociación de Universidades Confiadas a la Compañía de Jesús en América Latina, AUSJAL
Av. Santa Teresa de Jesús Edif. Cerpe, Piso 2, Oficina AUSJAL Urb.
La Castellana, Chacao (1060) Caracas - Venezuela
Tel/Fax (+58-212)-266-13-41 /(+58-212)-266-85-62

Nuestras redes sociales

facebook Facebook

twitter Twitter

youtube Youtube

Asociaciones Jesuitas en el mundo
Ausjal en el mundo AJCU AUSJAL JESAM JCEP JCS JCAP