Show simple item record

[en] CRITICAL ANALYSIS FOR DIFFERENT AVAILABLE METHODOLOGIES FOR HUMIDITY MEASUREMENT TO BE USED BY A CALIBRATION LABORATORY

dc.contributorALCIR DE FARO ORLANDO
dc.contributorALCIR DE FARO ORLANDO
dc.creatorLUIZ ALBERTO DOS SANTOS LIMA
dc.date2004-11-12
dc.date.accessioned2022-09-21T21:44:11Z
dc.date.available2022-09-21T21:44:11Z
dc.identifierhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=5705@1
dc.identifierhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=5705@2
dc.identifierhttp://doi.org/10.17771/PUCRio.acad.5705
dc.identifier.urihttps://hdl.handle.net/20.500.12032/42966
dc.description[pt] Recentemente, a umidade vem sendo um dos parâmetros cujas necessidades de medição e controle mais se desenvolvem especialmente em processos os farmacêuticos, de biotecnologia, automobilísticos, além de instalações de ar condicionado. A necessidade de expansão da rede de laboratórios de calibração de umidade, rastreados à Rede Brasileira de Calibração, torna-se cada vez maior para atender a demanda da indústria, além de contribuir para a melhoria dos níveis de incerteza de medição. Este trabalho tem como objetivo uma análise crítica das diferentes metodologias de medição de umidade para uso em laboratórios de calibração. Foram avaliadas as mais utilizadas expressões para a pressão parcial de vapor, visando o cálculo de umidade, e foi realizada uma comparação com a formulação de Sonntag, a mais aceita na comunidade metrológica internacional. Foi também analisada uma comparação entre alguns dos softwares disponíveis na internet para o cálculo dos principais parâmetros de umidade, tomando como referência a mesma formulação. Dentre os fatores de possível influência nas medições de umidade, foi avaliado o comportamento da mistura ar seco-vapor d´água como gás ideal e real, bem com as alterações na composição do ar. Foi feita uma análise das principais fontes de incerteza de medição seguindo a metodologia de medição de umidade a partir da temperatura de ponto de orvalho. Finalmente, o objetivo deste trabalho é apresentar aos laboratórios de calibração de umidade uma análise crítica das metodologias disponíveis para medição de umidade, juntamente com as incertezas alcançadas.
dc.description[en] Recently, the need of humidity measurement and control has been shown to be of growing interest, especially in processes like pharmaceuticals, biotechnology, automotives, as well as in air conditioning installations. Increasing the number of laboratories, which are traceable to the Brazilian Calibration Network, is a requirement for attending the industry demands, besides contributing towards improving the measurement uncertainty level. This work has as an objective to critically analyze different methods for humidity measurement, to be used by calibration laboratories. The mostly used expressions for calculating vapor partial pressure were evaluated, aiming humidity determination in comparison with Sonntag´s one, the most accepted formulation by the international metrological community. Also, a comparison was made between different softwares, which were available through internet, for calculating the most important humidity parameters, in comparison with results obtained by the same formulation. Among several factors, the dry air and water vapor mixture properties were calculated, considering it as an ideal or a real one, as well as the effect air composition changes on humidity measurement. The contribution of several sources of errors on the combined uncertainty of humidity measurement was examined, following the methodology that uses the dew point as a starting measurement parameter. Finally, the objective of this work is to present the humidity calibration laboratories a critical analysis of the available methodologies for measuring humidity, together with the achieved uncertainties.
dc.languagept
dc.publisherMAXWELL
dc.subject[pt] METROLOGIA
dc.subject[pt] PONTO DE ORVALHO
dc.subject[pt] UMIDADE
dc.subject[en] METROLOGY
dc.subject[en] DEW POINT
dc.subject[en] HUMIDITY
dc.title[pt] ANÁLISE CRÍTICA DAS DIVERSAS METODOLOGIAS DE MEDIÇÃO DE UMIDADE DISPONÍVEIS A SEREM UTILIZADAS POR UM LABORATÓRIO DE CALIBRAÇÃO
dc.title[en] CRITICAL ANALYSIS FOR DIFFERENT AVAILABLE METHODOLOGIES FOR HUMIDITY MEASUREMENT TO BE USED BY A CALIBRATION LABORATORY
dc.typeTEXTO


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record


© AUSJAL 2022

Asociación de Universidades Confiadas a la Compañía de Jesús en América Latina, AUSJAL
Av. Santa Teresa de Jesús Edif. Cerpe, Piso 2, Oficina AUSJAL Urb.
La Castellana, Chacao (1060) Caracas - Venezuela
Tel/Fax (+58-212)-266-13-41 /(+58-212)-266-85-62

Nuestras redes sociales

facebook Facebook

twitter Twitter

youtube Youtube

Asociaciones Jesuitas en el mundo
Ausjal en el mundo AJCU AUSJAL JESAM JCEP JCS JCAP