[pt] PROCEDIMENTO EXPERIMENTAL PARA AVALIAÇÃO METROLÓGICA DO DESEMPENHO DE UMA MICROTURBINA UTILIZADA PARA GERAÇÃO DE ENERGIA ELÉTRICA

dc.contributorALCIR DE FARO ORLANDO
dc.contributorALCIR DE FARO ORLANDO
dc.creatorALEX SANDER ASSUNCAO
dc.date2004-09-15
dc.date.accessioned2022-09-21T21:44:05Z
dc.date.available2022-09-21T21:44:05Z
dc.identifierhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=5467@1
dc.identifierhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=5467@2
dc.identifierhttp://doi.org/10.17771/PUCRio.acad.5467
dc.identifier.urihttps://hdl.handle.net/20.500.12032/42883
dc.description[pt] O uso de tecnologias para incrementar a geração distribuída de energia elétrica, particularmente microturbinas a gás, tem aumentado ultimamente devido à crise de energia que muitos países, como o Brasil têm passado o que é um incentivo à produção independente de energia elétrica. Procedimentos têm sido desenvolvidos para verificar os dados de desempenho de microturbinas, com objetivo de comissionamento. Quando alguém compra um sistema de geração de energia, sua partida pode apenas ser efetivada quando os dados do fabricante concordam com os de projeto, dentro de uma faixa de incerteza acordada, qualificando, portanto, estudos de viabilidade anteriormente realizados. Muitos procedimentos são detalhados para verificar os dados de desempenho sob condições de teste, extrapolando-os para outras diferentes. Potência, consumo de gás, emissão dos gases, qualidade da energia elétrica (incluindo distorção harmônica e frequência) estão entre os parâmetros normalmente medidos. A freqüência de aquisição de dados é normalmente especificada para atender as características de desempenho do equipamento sob condições estáveis de teste. Também, a incerteza dos instrumentos de medição é normalmente especificada, sem qualquer referência à incerteza expandida dos parâmetros calculados, que são usados para caracterizar seu desempenho. Este trabalho descreve um método para avaliação dos dados de desempenho de uma microturbina a gás, juntamente com uma metodologia para calcular a incerteza dos parâmetros que caracterizam seu desempenho, com objetivos de comissionamento, a partir da incerteza dos instrumentos de medição, e fazendo uma análise crítica dos objetivos de medição a serem alcançados. A metodologia é baseada nos conceitos metrológicos mais recentes, de forma que resultados confiáveis possam ser alcançados, utiliza condições de referência, estabelecidas por norma internacional [ISO-2314, 1973], para especificação dos dados de desempenho dos equipamentos, com objetivo de comparação, e segue as diretrizes da U.S. Enveronmental Protection Agency para especificação do desempenho a ser alcançado.
dc.description[en] The use of technologies for increasing distributed electric energy generation, particularly gas fired microturbines, has been lately growing due to the energies crisis many countries, including Brasil, have experienced, which is an incentive to an independent electric energy production. Procedures have been developed to check microturbine performance data for commissioning purposes. When somebody buys an energy production plant, its start-up can only be accomplished when manufacturers data matches the design data within an agreed uncertainty band, thus qualifying the previously made feasibility studies. Many procedures are detailed for checking the performance data under testing conditions, and extrapolating them for different ones. Power, gas consumption, gas emissions, electric energy quality (including harmonic distortion and frequency) are among the usually measured parameters. Data acquisition frequency is usually specified to match specified equipment behaviour under stable test conditions. Also, the uncertainty of the measurement instruments are usually specified, without, however, defining the expanded uncertainty of the calculated parameters, which are used to characterize their performance. This work presents a method for evaluating the gas fired microturbine performance data for electric energy generation, together with a methodology for calculating the uncertainty of parameters that characterize its performance for commissioning purposes, starting up from the uncertainty of the measurement instruments, and making a critical analysis of the measurement goals. The methodology is based on most recently used metrology concepts, so that reliable results can be achieved, uses ISO reference conditions for specifying equipment performance data for comparison purposes and follows U.S. Environment Protection Agency directions for specifying performance goals.
dc.languagept
dc.publisherMAXWELL
dc.subject[pt] GAS NATURAL
dc.subject[pt] GERACAO DE ENERGIA
dc.subject[pt] MICROTURBINAS A GAS
dc.subject[pt] COMISSAO
dc.subject[pt] METROLOGIA
dc.subject[en] NATURAL GAS
dc.subject[en] ENERGY GERATION
dc.subject[en] MICROTURBINE
dc.subject[en] COMMISSIONING
dc.subject[en] METROLOGY
dc.title[en] EXPERIMENTAL PROCEDURE FOR A METROLOGICAL EVALUATION OF THE PERFORMANCE OF A MICROTURBINE USED FOR ELECTRIC ENERGY GENERATION
dc.title[pt] PROCEDIMENTO EXPERIMENTAL PARA AVALIAÇÃO METROLÓGICA DO DESEMPENHO DE UMA MICROTURBINA UTILIZADA PARA GERAÇÃO DE ENERGIA ELÉTRICA
dc.typeTEXTO


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record


© AUSJAL 2022

Asociación de Universidades Confiadas a la Compañía de Jesús en América Latina, AUSJAL
Av. Santa Teresa de Jesús Edif. Cerpe, Piso 2, Oficina AUSJAL Urb.
La Castellana, Chacao (1060) Caracas - Venezuela
Tel/Fax (+58-212)-266-13-41 /(+58-212)-266-85-62

Nuestras redes sociales

facebook Facebook

twitter Twitter

youtube Youtube

Asociaciones Jesuitas en el mundo
Ausjal en el mundo AJCU AUSJAL JESAM JCEP JCS JCAP