Show simple item record

[en] TREATEMENT WASTEWATER EFFLUENTS CONTAINING HYDRAZINE

dc.contributorLUIZ ALBERTO CESAR TEIXEIRA
dc.creatorRONALD DA SILVA REIS
dc.date2004-06-30
dc.date.accessioned2022-09-21T21:43:53Z
dc.date.available2022-09-21T21:43:53Z
dc.identifierhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=5112@1
dc.identifierhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=5112@2
dc.identifierhttp://doi.org/10.17771/PUCRio.acad.5112
dc.identifier.urihttps://hdl.handle.net/20.500.12032/42725
dc.description[pt] No Brasil está em larga expansão o uso de geração de eletricidade por termoeléctricas. Na geração de eletricidade por usinas térmicas são utilizados grandes quantidades de água e produtos químicos, que após utilização geram efluentes. A hidrazina é um produto químico usado para controle de corrosão em águas de caldeiras, sistemas de vapor e outros sistemas de usinas térmicas que após utilização acaba incorporada aos efluentes líquidos destas usinas. Com intuito de promover uma sistemática de controle de efluentes produzidos nas usinas, procurou-se, nesta dissertação, estudar efluentes contendo hidrazina com enfoque tecnológico. O processo abordado neste estudo consistiu no tratamento de efluentes contendo hidrazina, utilizando peróxido de hidrogênio com auxílio de catalisador de íons de cobre, para decomposição da hidrazina. Os ensaios foram feitos em laboratório, utilizando-se efluentes sintéticos com concentrações pré- determinadas de hidrazina que variaram entre 10 e 100 mg/L, com controle do pH que variou em 7 e 9,5, temperatura fixada em 220C, com adição de concentrações calculadas de peróxido de hidrogênio e catalisador de sulfato de cobre. Concluiu-se que o processo é viável para reduzir a concentração de hidrazina em efluentes a níveis inferiores aos limites da legislação (1 mg/L), utilizando-se quantidades estequiométricas de peróxido de hidrogênio em conjunto com sulfato de cobre em concentrações de 1 mg/L de Cu 2+ como catalisador, em efluentes com pH 9,5, a temperatura ambiente, em tempos inferiores a 30 minutos. Assim sendo, o trabalho mostrou-se adequado para satisfazer as condições de descarte de efluentes em águas brasileiras de acordo com a resolução CONAMA 20, carta P-031/01 cláusula 2 artigo V, de 9 de Fevereiro de 2001.
dc.description[en] In Brazil, the use of energy produced by power plant generators is in expansion. Power plants use large quantities of water and chemical products that after use end up in effluents. Hydrazine is used in water systems for corrosion control, because of its excelents oxygen scavenging capacity. The present work was conducted to study the treatment of effluents containing hydrazine, under a technological approach, with the purpose of contributing to a systematic of effluents control in power stations. The process studied in this work was the decomposition of hydrazine with hydrogen peroxid in presence catalyst cooper íon. The experiments were made in laboratory scale, using synthetic effluents with initial concentration of hydrazine at the levels 10 and 100 mg/L, with initial pH values 7 and 9,5, temperature fixed at 220C, with addition of st oichiometric amounts of hydrogen peroxide, with and without addition of cooper ion catalyst. It was conclued that the process its viable for reduction of hydrazine concentration in effluents with pH 9,5, below to levels under legislation (1mg/L), using stoichiometric amounts of hydrogen peroxide together with 1 mg/L of cooper ion, in times less that 30 minutes and ambient temperature. Therefore this work showed that the process is adequate in satisfying the Brazilian legislation for discharge of effluents into water bodies according to regulation CONAMA 20, letter P-031/01 clause 2 article V, 09 February 2001.
dc.languagept
dc.publisherMAXWELL
dc.subject[pt] PEROXIDO DE HIDROGENIO
dc.subject[pt] TRATAMENTO DE EFLUENTES
dc.subject[pt] TERMOELECTRICAS
dc.subject[pt] HIDRAZINA
dc.subject[en] HYDROGEN PEROXIDE
dc.subject[en] EFFLUENT TREATMENT
dc.subject[en] POWER STATION
dc.subject[en] HYDRAZINE
dc.title[pt] TRATAMENTO OXIDATIVO DE EFLUENTES CONTENDO HIDRAZINA
dc.title[en] TREATEMENT WASTEWATER EFFLUENTS CONTAINING HYDRAZINE
dc.typeTEXTO


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record


© AUSJAL 2022

Asociación de Universidades Confiadas a la Compañía de Jesús en América Latina, AUSJAL
Av. Santa Teresa de Jesús Edif. Cerpe, Piso 2, Oficina AUSJAL Urb.
La Castellana, Chacao (1060) Caracas - Venezuela
Tel/Fax (+58-212)-266-13-41 /(+58-212)-266-85-62

Nuestras redes sociales

facebook Facebook

twitter Twitter

youtube Youtube

Asociaciones Jesuitas en el mundo
Ausjal en el mundo AJCU AUSJAL JESAM JCEP JCS JCAP