Show simple item record

[en] STUDY OF THE STABLE AND METASTABLE (LIF)NLI+ ION EMISSION INDUCED BY 252CF FISSION FRAGMENTS

dc.contributorENIO FROTA DA SILVEIRA
dc.creatorRAFAEL MARTINEZ RODRIGUEZ
dc.date2004-01-14
dc.date.accessioned2022-09-21T21:42:14Z
dc.date.available2022-09-21T21:42:14Z
dc.identifierhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=4384@1
dc.identifierhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=4384@2
dc.identifierhttp://doi.org/10.17771/PUCRio.acad.4384
dc.identifier.urihttps://hdl.handle.net/20.500.12032/42483
dc.description[pt] Um espectrômetro de massa por tempo-de-vôo 252Cf-PDMS foi empregado para a realização de três atividades: a) o aperfeiçoamento do espectrômetro com a instalação de novos dispositivos; b) a análise da emissão secundária de agregados iônicos por um alvo de LiF; c) a análise da fragmentação em vôo de íons positivos (LiF)nLi+ metaestáveis. O aperfeiçoamento do espectrômetro consistiu: i) na blindagem elétrica do detector start para aumentar a sua estabilidade; ii) na caracterização de dois pares de placas defletoras já existentes; iii) na instalação de um novo tipo de detector sensível à posição com anodo multi-fios, e iv) no projeto e na instalação de uma lente Einzel para aumentar a transmissão de íons secundários entre a amostra e o detector. A emissão secundária de agregados iônicos por um filme de LiF policristalino, bombardeado por fragmentos de fissão de ~ 60 MeV foi analisada através da técnica tempo-de-vôo (TOF). O detector sensível à posição recém instalado permite o emprego da técnica XY-TOF para analisar distribuições angulares de íons Li e dos agregados (LiF)nLi+. Determinaram-se as distribuições angulares dos agregados com n = 0 a 3, através de medidas simultâneas de suas velocidades axiais e radiais, evento por evento. A vida media de íons metaestáveis (LiF)nLi+* é determinada fazendo uso da configuração do espectrômetro e especialmente do comprimento do tubo de vôo livre. Após serem emitidas, as espécies iônicas metaestáveis monocarregadas são aceleradas por um campo elétrico da ordem de 2 kV/mm, e conduzidas a uma região de campo externo nulo, onde podem se dissociar espontaneamente em um fragmento iônico e outro neutro. Para facilitar a analise dos dados, impede-se a detecção do fragmento iônico através de um filtro eletrostático. Foram analisados os agregados iônicos com n = 1 a 5. Encontrouse que os valores das vidas medias estão na faixa de 30 a 100 ns. Discute-se também a detecção de espécies neutras produzidas por colisão de agregados (LiF)nLi+ com moléculas de gás residual.
dc.description[en] A 252Cf-PDMS time-of-flight mass spectrometer was used for the accomplishment of three activities: a) improvement of the spectrometer by introducing new devices; b) analysis of the LiF cluster ion secondary emission; c) analysis of the (LiF)nLi+ metastable íon fragmentation, in flight. The spectrometer improvement consists of: i) the shielding of the start detector to increase its stability, ii) the characterization of two existing deflecting- plate pairs, iii) the installation of a new type of position-sensitive delay line detector for secundary ions, and iv) the project and manufacture of a Einzel lens to increase the transmission of the secondary íons between the sample and the detector. The secondary cluster ion emission of policrystalline LiF, induced by the impact of fission fragments (60 MeV), is analyzed by the time-of-flight technique (TOF). The new position sensitive delay-line detector allows the use of the XY-TOF technique to analyze angular distributions of Li ions and (LiF)nLi+ clusters. Event by event, their axial and radial velocities are measured simultaneously, allowing the angular distributions measurement of clusters with n = 0 to 3. Mean lives of metastable clusters are determined through the measurement of the detection rate dependence on the target bias. After been emitted, the monocharged metatable ions are acelerated by a 2 kV/mm electric field towards a field-free region, where they can spontaneously dissociateinto two fragments, one ion and another neutral. To facilitate the data analysis, it is avoided the detection of ionic fragments by placing an electrostatic filter in front of the detector. Mean lives values of 30 to 100 ns are determined for ionic clusters with n = 1 to 5. The production of neutral species by collision of the (LiF)nLi+ clusters with the gas molecules is also discussed.
dc.languagept
dc.publisherMAXWELL
dc.subject[pt] EMISSAO IONS SECUNDARIOS
dc.subject[pt] VELOCIDADES INICIAIS
dc.subject[pt] TEMPO DE VIDA MEDIO
dc.subject[pt] METAESTAVEIS
dc.subject[pt] TEMPO DE VOO
dc.subject[en] SECUNDARY ION EMISSION
dc.subject[en] INITIAL VELOCITIES
dc.subject[en] MEAN LIFE TIME
dc.subject[en] METASTABLES
dc.subject[en] TIME OF FLIGHT
dc.title[pt] ESTUDO DA EMISSÃO DE ÍONS ESTÁVEIS E METAESTÁVEIS (LIF)NLI+ INDUZIDA POR FRAGMENTOS DE FISSÃO DO 252CF
dc.title[en] STUDY OF THE STABLE AND METASTABLE (LIF)NLI+ ION EMISSION INDUCED BY 252CF FISSION FRAGMENTS
dc.typeTEXTO


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record


© AUSJAL 2022

Asociación de Universidades Confiadas a la Compañía de Jesús en América Latina, AUSJAL
Av. Santa Teresa de Jesús Edif. Cerpe, Piso 2, Oficina AUSJAL Urb.
La Castellana, Chacao (1060) Caracas - Venezuela
Tel/Fax (+58-212)-266-13-41 /(+58-212)-266-85-62

Nuestras redes sociales

facebook Facebook

twitter Twitter

youtube Youtube

Asociaciones Jesuitas en el mundo
Ausjal en el mundo AJCU AUSJAL JESAM JCEP JCS JCAP