Show simple item record

[en] KINETICS ASPECTS OF CHROMIUM (III) REMOVAL BY PRECIPITATE FLOTATION

dc.contributorMAURICIO LEONARDO TOREM
dc.creatorBELENIA YANETH MEDINA BUENO
dc.date2003-12-22
dc.date.accessioned2022-09-21T21:42:10Z
dc.date.available2022-09-21T21:42:10Z
dc.identifierhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=4325@1
dc.identifierhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=4325@2
dc.identifierhttp://doi.org/10.17771/PUCRio.acad.4325
dc.identifier.urihttps://hdl.handle.net/20.500.12032/42428
dc.description[pt] Metais pesados contidos em efluentes industriais são fontes de grande potencial de degradação ambiental; visto que eles produzem alterações físicoquímicas na qualidade da água. Estas alterações têm um impacto direto na mortandade da flora e fauna afetando indiretamente a saúde dos seres humanos. Esta dissertação refere-se ao estudo dos aspectos cinéticos da remoção de cromo (III) por flotação de precipitados a partir de cloreto de cromo hexahidratado, utilizando dodecilsulfato de sódio (DSS) como coletor aniônico. Para este estudo, foram realizadas medidas de potencial zeta, bem como ensaios de flotação do cromo (III) para determinar os parâmetros adequados de operação: vazão de ar, concentração de coletor e concentração de espumante. Medições de potencial zeta das partículas de hidróxido de cromo na presença de eletrólito indiferente KCl, indicaram ponto isoelétrico (PIE) em pH em torno de 8,5. A presença do coletor aniônico (DSS) no sistema hidróxido de cromo-água indicou uma redução do potencial zeta, para os três níveis de concentrações investigados. Havendo um deslocamento do PIE na direção de valores de pH mais inferiores, atribuindo tal comportamento à adsorção do coletor sobre o Cr(OH)3 através de interação eletrostática. Com relação aos resultados dos ensaios de flotação de precipitados do cromo (III), obtiveram-se remoções de aproximadamente 96,2%, conseguindo-se chegar a valores inferiores ao estabelecido pela norma do CONAMA (20/86), ou seja, [Cr3+]£0,5 mg/L. O estudo da cinética da flotação mediante as análises integral e diferencial evidenciaram que o processo de remoção do precipitado de hidróxido de cromo segue um modelo de primeira ordem.
dc.description[en] Heavy metals contained in industrial effluents are sources of great potential environmental degradation, since their presence produce physicochemical alterations harming in the quality of the water. These alterations have a direct impact in the mortality of the flora and fauna affecting indirectly the human health. This dissertation refers to the study of the kinetic aspects of chromium (III)removal by precipitate flotation from chromium chloride (CrCl3.6H2O), using sodium dodecylsulfate (SDS) as anionic collector. For this study, measurements of zeta potential were accomplished as well as chromium (III) tests of flotation to determine the appropriate parameters operation: gas flow rate, concentration of collector and frother. Measurements of zeta potential of the particles of chromium (III) hydroxide in the presence of indifferent electrolyte KCl, indicated an isoelectric point (PIE)in pH around 8,5. The particles of chromium (III) hydroxide in the presence of anionic collector (SDS) showed a decrease in module of the zeta potential, for the three levels of concentrations investigated, as well as a displacement of the PIE in the direction of the more inferior pH values. This behavior can be attributed to the adsorption of the anionic collector on Cr(OH)3 due to the electrostatic attraction. Chromium (III) removals of 96,2% were obtained by precipitate flotation. Residual values of chromium reached are lower than the standards values established by the CONAMA (20/86), that mean [Cr3+]£0,5 mg/L. The kinetic flotation study showed that the removal of chromium (III)hydroxide precipitates followed a first order model.
dc.languagept
dc.publisherMAXWELL
dc.subject[pt] CINETICA DE FLOTACAO
dc.subject[pt] CROMO III
dc.subject[pt] FLOTACAO DE PRECIPITADOS
dc.subject[pt] EFLUENTES LIQUIDOS
dc.subject[en] KINETICS FLOTATION
dc.subject[en] CHROMIUM III
dc.subject[en] PRECIPITATE FLOTATION
dc.subject[en] LIQUIDS EFFLUENTS
dc.title[pt] ASPECTOS CINÉTICOS DA REMOÇÃO DE CROMO (III) POR FLOTAÇÃO DE PRECIPITADOS
dc.title[en] KINETICS ASPECTS OF CHROMIUM (III) REMOVAL BY PRECIPITATE FLOTATION
dc.typeTEXTO


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record


© AUSJAL 2022

Asociación de Universidades Confiadas a la Compañía de Jesús en América Latina, AUSJAL
Av. Santa Teresa de Jesús Edif. Cerpe, Piso 2, Oficina AUSJAL Urb.
La Castellana, Chacao (1060) Caracas - Venezuela
Tel/Fax (+58-212)-266-13-41 /(+58-212)-266-85-62

Nuestras redes sociales

facebook Facebook

twitter Twitter

youtube Youtube

Asociaciones Jesuitas en el mundo
Ausjal en el mundo AJCU AUSJAL JESAM JCEP JCS JCAP