Show simple item record

[en] IMPLEMENTACION OF A 4(PI )(GAMA) SYSTEM, WITH WELL TYPE NAI(TI) DETECTOR, FOR CALIBRATION OF GAMMA EMITTERS RADIONICLIDES

dc.contributorGERALDO MONTEIRO SIGAUD
dc.contributorLUIZ TAUHATA
dc.contributorROBERTO POLEDNA
dc.creatorDOUGLAS CISNEIROS DE BARROS
dc.date2001-11-06
dc.date.accessioned2022-09-21T21:40:03Z
dc.date.available2022-09-21T21:40:03Z
dc.identifierhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=2070@1
dc.identifierhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=2070@2
dc.identifierhttp://doi.org/10.17771/PUCRio.acad.2070
dc.identifier.urihttps://hdl.handle.net/20.500.12032/41785
dc.description[pt] Os métodos de calibração absoluta para a determinação da atividade de radionuclídeos mais utilizados nos laboratórios de metrologia são o 4(Pi Beta - Gama) (contagem de coincidências), pico-soma (coincidência Gama - Gama ou X- Gama), o 4(PI,Gama) e o contagem em ângulo sólido definido.O método 4(PI Gama) é especialmente indicado na medição da atividade de radionuclídeos que apresentam esquema de decaimento complexo. Ele se baseia no cálculo da eficiência total do sistema de medição para um determinado radionuclídeo, através dos valores da eficiência total referente a cada raio gama do esquema de decaimento do mesmo radionuclídeo. Este cálculo é expresso, para um ramo do decaimento, pela equação: EpsilomT = 1 - Produtório ( 1 - EpsilomTi ) (Confirma símbolos no resumo na tese) , onde EpsilomT é a eficiência global para cada decaimento em cascata e EpsilomTi a eficiência total para cada transição gama da cascata. A equação completa leva em conta o número de ramos e a probabilidade de cada raio gama. Os (Confirmar os símbolos no resumo na tese)Ti são obtidos a partir da curva eficiência x energia do sistema.O método do pico- soma é aplicado na determinação da atividade para fontes emitindo pelo menos dois raios gama subsequentes. Neste trabalho é apresentado o procedimento experimental, após a implementação dos métodos 4(Pi Gama) e pico-soma no Laboratório Nacional de Metrologia das Radiações Ionizantes - LNMRI, com a finalidade de expandir os serviços de fornecimento de fontes radioativas aos usuários, tanto em quantidade quanto em faixa de atividade ampliada.Os padrões radioativos utilizados no levantamento da curva de calibração eficiência total x energia, na aplicação do método pico-soma e na validação do método 4(Pi) foram: 241Am, 210Pb, 54Mn, 57 Co, 60Co , 109Cd, 113Sn, 134Cs, 137Cs, 139 Ce e 88Y. Para verificar o desempenho dos métodos implantados, foram calibrados os radionuclídeos: 139 Ce, 60Co, 88Y e 134Cs, e comparados com os valores padronizados com o sistema absoluto 4 (Pi beta - gama). Os resultados encontrados foram consistentes com os obtidos pelo método de padronização absoluta 4 (Pi beta - gama) .
dc.description[en] Among the absolute calibration methods for activity quantity of radionuclides the most used in the metrology laboratories are: the 4(Pi Beta - Gama) (coincidence counting), defined solid angle counting, sum-peak (or Gama - Gama coincidence) and 4(Pi Gama) method. The 4( Pi Gama) method is appropriate to measure the activity of radionuclides with complex decay scheme and its implementation at Laboratório Nacional de Metrologia das Radiações Ionizantes, commissioned by INMETRO from 1989, will provide to the expansion of the jobs to supply the users by standard radioactive sources.The determination of activity can be made using calibration factor and/or the efficiency curve. For the implantation of this calibration method at LNMRI, after the selection of the detector and the electronic instrumentation, the attainment of the eficiency curve in function of gamma rays energy, standard sources with one or two peaks each were used. The method is based in (Epsilon)T = 1 - Produtórioi (1 - Ti) where EpsilonT is the total efficiency for each radionuclide and EpsilonTi is the efficiency for each gamma transition of this radionuclide. The detector selected was a 8``x 8`` well type NaI(Tl), with well dimensions 6`` deep and 3`` of diameter, from Harshaw The standards sources used are: Am-241, Pb-210, Mn-54, Co-57, Cd-109, Ce-139, Co-60, Na-22, Y-88 and Zn-65. The preliminary results are consistent with the literature.
dc.languagept
dc.publisherMAXWELL
dc.subject[pt] CALIBRACAO
dc.subject[pt] DETETOR DE NAI(TI) TIPO POCO
dc.subject[pt] METODO PICO-SOMA
dc.subject[pt] PADRONIZACAO DE RADIONUCLIDEOS
dc.subject[en] CALIBRATION
dc.subject[en] WELL TYPE NAI(TI) DETECTOR
dc.subject[en] SUM-PEAK METHOD
dc.subject[en] STANDARDIZATION OF RADIONUCLIDES
dc.title[pt] IMPLANTAÇÃO DE UM SISTEMA 4(PI)(GAMA), COM DETECTOR DE NAI(TI), TIPO POÇO, PARA A CALIBRAÇÃO DE RADIONUCLÍDEOS EMISSORES GAMA
dc.title[en] IMPLEMENTACION OF A 4(PI )(GAMA) SYSTEM, WITH WELL TYPE NAI(TI) DETECTOR, FOR CALIBRATION OF GAMMA EMITTERS RADIONICLIDES
dc.typeTEXTO


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record


© AUSJAL 2022

Asociación de Universidades Confiadas a la Compañía de Jesús en América Latina, AUSJAL
Av. Santa Teresa de Jesús Edif. Cerpe, Piso 2, Oficina AUSJAL Urb.
La Castellana, Chacao (1060) Caracas - Venezuela
Tel/Fax (+58-212)-266-13-41 /(+58-212)-266-85-62

Nuestras redes sociales

facebook Facebook

twitter Twitter

youtube Youtube

Asociaciones Jesuitas en el mundo
Ausjal en el mundo AJCU AUSJAL JESAM JCEP JCS JCAP