Show simple item record

[es] EVALUACIÓN DE LIGADURAS VIGA-COLUMNA EN EXTRUCTURAS DE ACERO SOMETIDAS A FEXIÓN EN EL EJE DE MENOR INERCIA;
[en] EVALUATION OF THE STRUCTURAL BEHAVIOR OF BEAM-COLUMN SEMI-RIGID STEEL CONNECTIONS WORKING IN THE COLUMN MINOR AXIS

dc.contributorSEBASTIAO ARTHUR LOPES DE ANDRADE
dc.contributorSEBASTIAO ARTHUR LOPES DE ANDRADE
dc.contributorPEDRO COLMAR GONCALVES DA SILVA VELLASCO
dc.creatorLUCIANO RODRIGUES ORNELAS DE LIMA
dc.date2001-02-19
dc.date.accessioned2022-09-21T21:39:49Z
dc.date.available2022-09-21T21:39:49Z
dc.identifierhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=1264@1
dc.identifierhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=1264@2
dc.identifierhttps://www.maxwell.vrac.puc-rio.br/colecao.php?strSecao=resultado&nrSeq=1264@4
dc.identifierhttp://doi.org/10.17771/PUCRio.acad.1264
dc.identifier.urihttps://hdl.handle.net/20.500.12032/41593
dc.description[pt] As ligações estruturais desempenham um papel fundamental no comportamento global das estruturas de aço. Muitos ensaios experimentais desta ligações têm sido desenvolvidos para que se possa avaliar corretamente a influência dos parâmetros físicos e geométricos que influenciam no comportamento destas ligações. Hoje em dia, as ligações no eixo de menor inércia da coluna de pórticos contraventados são dimensionadas como flexíveis. Maiores problemas ocorrem quando este contraventamento não é possível e as ligações rígidas são utilizadas. Todavia, garantir que esta ligação tenha um comportamento rígido, principalmente no eixo de menor inércia, é algo um tanto quanto discutível. Sendo assim, a utilização de ligações semi-rígidas tornou-se viável porque tem um comportamento estrutural que melhor se aproxima da realidade e ainda possibilita uma diminuição do preço final da estrutura. Este trabalho apresenta uma avaliação do comportamento estrutural de ligações viga-coluna em estruturas de aço no eixo de menor inércia. Uma investigação dos modelos existentes de ligações semi- rígidas na literatura foi realizada e identificou dois modelos estruturais fundamentais para esta investigação: o de Kishi e Chen para o eixo de maior inércia e o de Teixeira Gomes para a menor inércia. Os sistemas de classificação de ligações existentes foram avaliadas mas ainda não se tem conhecimento de um sistema específico para o eixo de menor inércia ou da validade do uso dos sistemas de classificação gerados para maior inércia quando aplicados na menor inércia. Uma análise experimental onde três ensaios de ligação de aço viga x coluna, em escala real foi executada. Esta análise possibilitou a determinação da curva momento x rotação, resistência a flexão da ligação, evolução das tensões e deformações e possíveis modos de ruína. O presente trabalho também propõe um modelo preliminar de ligação semi-rígida com dupla cantoneira de alma e cantoneira de apoio, ou enrijecedor, no eixo de menor inércia visando sua utilização em edificações de estruturas de aço. Uma validação deste modelo preliminar foi realizada através de uma comparação com os resultados experimentais gerados.
dc.description[en] Connections perform a fundamental hole in the steel structure´s global behaviour. In order to evaluate the real influence of the physical and geometrical parameters that controls their behaviour, many experimental tests and analysis have been developed but a definitive answer to the problem in question still stands. Nowadays, the non-sway portal frame design still adopts bolted flexible connections in the column´s minor axis. Unfortunately, in the case of sway frames, the majority of connections are rigid, despite the fact that rigid connections have higher costs and rigid connections in the column minor axis have questionable true behaviour. To overcome these difficulties the use of semi-rigid connections can decrease the global structure cost, having an extra advantage of being closer to reality. This background served as motivation for the present investigation on the an evaluation of the structural behaviour of beam-column semi-rigid steel connections working in the column minor axis. A literature survey on the semi-rigid models currently in use in literature was accomplished. Two fundamental structural models were identified: the Kishi and Chen model for the bending on the column major axis and the model proposed by Gomes for the minor axis bending. A specific connection classification system developed for the major axis for the column minor axis was not found in the literature. The use of general classification for this task still deserves a validations study. An experimental programme consisting of three full scale tests of beam to column connections was carried out. This analysis enable the assessment of the moment versus rotation curve, moment capacity of the connection, stress patterns, strains and collapse mechanisms. This work also presents a preliminary semi-rigid model for the column´s minor axis, made with a double web angle and a support angle or a stiffner. A validation study of this preliminary model was accomplished through a comparison with the acquired experimental results.
dc.description[es] Las ligaduras extructurales desempeñam un papel fundamental en el comportamiento global de las extructuras de acero. Muchos ensayos experimentales han sido desarrollados para poder evaluar correctamente la influencia de los parámetros físicos y geométricos que influeyen en el comportamiento de estas ligaduras. Hoy en dia, las ligaduras en el eje de menor inercia de la columna de pórticos contraventados son dimensionadas como flexíbles. Mayores problemas ocurren cuando este contraventamento no es posible y se utilizan ligaduras rígidas. Pero garantizar que esta ligadura tenga un comportamiento rígido, principalmente en el eje de menor inercia, es algo bastante discutible. Así, la utilización de ligaduras semi-rígidas se hizo posible, porque tiene un comportamiento extructural que se aproxima mejor de la realidad y posibilita una diminuición del precio final de la extructura. Este trabajo presenta una evaluación del comportamiento extructural de ligaduras viga-columna en extructuras de acero en el eje de menor inercia. Se realizó una investigación de los modelos existentes de ligaduras semirígidas en la literatura y se identificó dos modelos extructurales fundamentales para esta investigación: el de Kishi y Chen para el eje de mayor inercia y el de Teixeira Gomes para el de menor inercia. Los sistemasde clasificación de ligaduras existentes fueron evaluados pero aún no se tiene conocimiento de un sistema específico para el eje de menor inercia o de la validad del uso de los sistemasde clasificación generados para mayor inercia cuando aplicados en menor inercia. Un análisis experimental donde tres ensayos de ligadura de acero viga x columna, en escala real fue ejecutada. Este análisis posibilitó la determinación de la curva momento x rotación, resistencia a la fexión de la ligadura, evolución de las tensiones y deformaciones y posibles modos de ruína. El presente trabajo propone un modelo preliminar de ligadura semirígida con dupla esquinera de alma y de apoyo, o enrijecedor, en el eje de menor inercia con el objetivo de utilizarlo en edificaciones de extructuras de acero. Una evaluación de este modelo preliminar fue realizada através de una comparación con los resultados experimentales generados.
dc.languagept
dc.publisherMAXWELL
dc.subject[pt] LIGACAO SEMI-RIGIDA MISTA
dc.subject[pt] ANALISE EXPERIMENTAL DE ESTRUTURA
dc.subject[pt] ESTRUTURA DE ACO
dc.subject[en] SEMI-RIGID CONNECTION
dc.subject[en] EXPERIMENTAL ANALYSIS OF STRUCTURES
dc.subject[en] STEEL STRUCTURE
dc.subject[es] CONECCIONE SEMIRIGIDA
dc.subject[es] ANALISIS EXPERIMENTAL DE EXTRUCTURAS
dc.subject[es] EXTRUCTURA DE ACERO
dc.title[pt] AVALIAÇÃO DE LIGAÇÕES VIGA-COLUNA EM ESTRUTURAS DE AÇO SUBMETIDAS À FLEXÃO NO EIXO DE MENOR INÉRCIA
dc.title[es] EVALUACIÓN DE LIGADURAS VIGA-COLUMNA EN EXTRUCTURAS DE ACERO SOMETIDAS A FEXIÓN EN EL EJE DE MENOR INERCIA
dc.title[en] EVALUATION OF THE STRUCTURAL BEHAVIOR OF BEAM-COLUMN SEMI-RIGID STEEL CONNECTIONS WORKING IN THE COLUMN MINOR AXIS
dc.typeTEXTO


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record


© AUSJAL 2022

Asociación de Universidades Confiadas a la Compañía de Jesús en América Latina, AUSJAL
Av. Santa Teresa de Jesús Edif. Cerpe, Piso 2, Oficina AUSJAL Urb.
La Castellana, Chacao (1060) Caracas - Venezuela
Tel/Fax (+58-212)-266-13-41 /(+58-212)-266-85-62

Nuestras redes sociales

facebook Facebook

twitter Twitter

youtube Youtube

Asociaciones Jesuitas en el mundo
Ausjal en el mundo AJCU AUSJAL JESAM JCEP JCS JCAP